{"items":[{"primaryId":"39873-700","Primary ID":"39873-700","Color":"Black","Marketing Product Category ":"Cabinets & Enclosures","Marketing Product Family/Group":"Accessories","Marketing Product Subgroup":"Thermal Management","Marketing Product Series":"Vertical Exhaust Duct For ZetaFrame Cabinet","Marketing Description - Global English":"Vertical Exhaust Duct For ZetaFrame®Cabinet; For 23.6\"W (600 mm) x 41.3\"D (1050 mm) - 47.2\"D (1200 mm) Cabinet; 15”H-20”H (381 mm – 508 mm); One Cable Opening; Black","Shipping Weight":18,"Shipping Weight Uom":"LB","Ship Height":6,"Ship Height Uom":"in","Ship Length/Depth":114,"Ship Length/Depth Uom":"in","Ship Width":24,"Ship Width Uom":"in","Shipping Weight (Metric)":8.16,"Shipping Weight Uom (Metric)":"kg","Shipping Height (Metric)":15,"Shipping Height Uom (Metric)":"cm","Shipping Width (Metric)":61,"Shipping Width Uom (Metric)":"cm","Msrp $ Usd":796.13,"Country Of Origin":"US","Certifications":["Not Applicable"],"Series Level Manual Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/a8d9feb5/66eca50606cc930019d6bbd2/ZETAFRAME_USER_MANUAL"],"Series Level Installation Instructions Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/c35d59b5/66eca58f06cc930019d6c0f8/39873_IIS"],"Promote on Website":"1","Attached to Series":"1","Height":"20\" (508 mm)","Width":"19.9\" (505 mm)","Depth":"23.6\" (599 mm)","Cabinet Width":"23.6\"W (600 mm)","Duct Height":"15”-20”H (381 mm – 508 mm)","BABA Compliant":"1","Product Height":20,"Product Height Uom":"\"","Product Length/Depth":23.6,"Product Length/Depth Uom":"\"","Product Width ":19.9,"Product Width Uom":"\"","Product Height (Metric)":508,"Product Height Uom (Metric)":"mm","Product Depth (Metric)":599,"Product Depth Uom (Metric)":"mm","Product Width (Metric)":505,"Product Width Uom (Metric)":"mm","Product Weight":15.8,"Product Weight UOM":"LB","Short Description":"VED,600W,15-20IN H,BK","Search Terms":"39873-700,Vertical Exhaust Duct For ZetaFrame Cabinet,ZetaFrame Vertical Exhaust Duct For ZetaFrame Cabinet,Server cabinet Vertical Exhaust Duct For ZetaFrame Cabinet,Rack-mounted Vertical Exhaust Duct For ZetaFrame Cabinet,Data center Vertical Exhaust Duct For ZetaFrame Cabinet,Cabinet Vertical Exhaust Duct For ZetaFrame Cabinet solution,Network rack Vertical Exhaust Duct For ZetaFrame Cabinet,Structured cabling solution for Vertical Exhaust Duct For ZetaFrame Cabinet,Best Vertical Exhaust Duct For ZetaFrame Cabinet for server racks,How to organize cables with Vertical Exhaust Duct For ZetaFrame Cabinet,Efficient routing for Vertical Exhaust Duct For ZetaFrame Cabinet,Front-to-back cable routing for Vertical Exhaust Duct For ZetaFrame Cabinet,High-density cable organization for Vertical Exhaust Duct For ZetaFrame Cabinet,Professional cable management for Vertical Exhaust Duct For ZetaFrame Cabinet","Search Relevancy":2,"SKU Level SEO Page Title":"Vertical Exhaust Duct - Drop Ceiling Return | Chatsworth","SKU Level SEO Meta Description":"Boost airflow with a vertical exhaust duct that creates a sealed drop ceiling air return for ZetaFrame® cabinets. Streamline cooling and protect equipment.","SKU Level Web H4 Heading":"Key Features of the Vertical Exhaust Duct","SKU Level Web Paragraph Text":"<p>The vertical exhaust duct provides a dedicated pathway for hot air to exit a ZetaFrame® cabinet, improving overall thermal performance. Its sealed design creates a reliable drop ceiling air return that isolates exhaust from surrounding equipment. This solution helps data‑center operators meet cooling efficiency targets while protecting sensitive hardware. Designed for cabinets with a depth of 41.3 in (1050 mm) or greater, the duct adjusts from 15 in to 20 in (381 mm‑508 mm) to match the distance to an overhead drop ceiling. The aluminum panels and plastic corners deliver durable construction, and the finish is available in black or Glacier White to match cabinet aesthetics. The part number 39873‑700 ensures compatibility with ZetaFrame® units and streamlines ordering. Airflow management is optimized by directing exhaust directly upward, reducing recirculation and lowering cooling costs. The flexible top seal accommodates minor variations in ceiling height, maintaining a tight seal for consistent performance. This vertical exhaust duct integrates with solid rear doors, bottom panels, and air directors for a complete containment strategy. Installation is straightforward, featuring a two‑piece design that bolts to the cabinet top and includes a brush‑sealed cable opening for power cords. An optional over‑track exhaust duct configuration can be added for extended routing needs in complex rack layouts. All required hardware is supplied, enabling rapid deployment without additional parts. By incorporating this exhaust cabinet accessory, facilities gain a scalable solution that supports high‑density deployments and future‑ready data‑center designs. The vertical exhaust duct enhances cooling reliability, simplifies maintenance, and aligns with CPI's commitment to quality and innovation. Contact a CPI sales specialist to confirm fit and begin integration.</p>"},{"primaryId":"39873-701","Primary ID":"39873-701","Color":"Black","Marketing Product Category ":"Cabinets & Enclosures","Marketing Product Family/Group":"Accessories","Marketing Product Subgroup":"Thermal Management","Marketing Product Series":"Vertical Exhaust Duct For ZetaFrame Cabinet","Marketing Description - Global English":"Vertical Exhaust Duct For ZetaFrame®Cabinet; For 27.6\"W (700 mm) x 41.3\"D (1050 mm) - 47.2\"D (1200 mm) Cabinet; 15”H-20”H (381 mm – 508 mm); One Cable Opening; Black","Shipping Weight":19,"Shipping Weight Uom":"LB","Ship Height":6,"Ship Height Uom":"in","Ship Length/Depth":114,"Ship Length/Depth Uom":"in","Ship Width":24,"Ship Width Uom":"in","Shipping Weight (Metric)":8.62,"Shipping Weight Uom (Metric)":"kg","Shipping Height (Metric)":15,"Shipping Height Uom (Metric)":"cm","Shipping Width (Metric)":61,"Shipping Width Uom (Metric)":"cm","Msrp $ Usd":800.77,"Country Of Origin":"US","Certifications":["Not Applicable"],"Series Level Manual Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/a8d9feb5/66eca50606cc930019d6bbd2/ZETAFRAME_USER_MANUAL"],"Series Level Installation Instructions Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/c35d59b5/66eca58f06cc930019d6c0f8/39873_IIS"],"Promote on Website":"1","Attached to Series":"1","Height":"20\" (508 mm)","Width":"23.8\" (605 mm)","Depth":"23.6\" (599 mm)","Cabinet Width":"27.6\"W (700 mm)","Duct Height":"15”-20”H (381 mm – 508 mm)","BABA Compliant":"1","Product Height":20,"Product Height Uom":"\"","Product Length/Depth":23.6,"Product Length/Depth Uom":"\"","Product Width ":23.8,"Product Width Uom":"\"","Product Height (Metric)":508,"Product Height Uom (Metric)":"mm","Product Depth (Metric)":599,"Product Depth Uom (Metric)":"mm","Product Width (Metric)":605,"Product Width Uom (Metric)":"mm","Product Weight":15.8,"Product Weight UOM":"LB","Short Description":"VED,700W,15-20IN H,BK","Search Terms":"39873-701,Vertical Exhaust Duct For ZetaFrame Cabinet,ZetaFrame Vertical Exhaust Duct For ZetaFrame Cabinet,Server cabinet Vertical Exhaust Duct For ZetaFrame Cabinet,Rack-mounted Vertical Exhaust Duct For ZetaFrame Cabinet,Data center Vertical Exhaust Duct For ZetaFrame Cabinet,Cabinet Vertical Exhaust Duct For ZetaFrame Cabinet solution,Network rack Vertical Exhaust Duct For ZetaFrame Cabinet,Structured cabling solution for Vertical Exhaust Duct For ZetaFrame Cabinet,Best Vertical Exhaust Duct For ZetaFrame Cabinet for server racks,How to organize cables with Vertical Exhaust Duct For ZetaFrame Cabinet,Efficient routing for Vertical Exhaust Duct For ZetaFrame Cabinet,Front-to-back cable routing for Vertical Exhaust Duct For ZetaFrame Cabinet,High-density cable organization for Vertical Exhaust Duct For ZetaFrame Cabinet,Professional cable management for Vertical Exhaust Duct For ZetaFrame Cabinet","Search Relevancy":2,"SKU Level SEO Page Title":"Cabinet Duct: Vertical Exhaust for ZetaFrame® | Chatsworth","SKU Level SEO Meta Description":"Discover a high‑performance cabinet duct that creates a sealed airflow path for ZetaFrame® cabinets, boosting cooling efficiency for exhaust cabinets.","SKU Level Web H4 Heading":"Key Benefits of the Vertical Exhaust Duct","SKU Level Web Paragraph Text":"<p>The vertical exhaust duct is a purpose‑built cabinet duct that mounts on the top of a ZetaFrame® cabinet, creating a sealed pathway for hot air to rise directly to an overhead drop ceiling. Its adjustable height accommodates ceiling clearances from 15″ to 20″ (381 mm-508 mm), ensuring reliable performance in diverse data‑center layouts. The design integrates a brush‑sealed cable opening, preserving the integrity of the airflow while allowing power cords to pass safely. By directing exhaust air upward, the duct enhances the efficiency of exhaust cabinets, reducing recirculation and supporting higher equipment densities. The flexible top seal adapts to minor variations in ceiling height, maintaining a continuous air barrier that supports optimal cooling for AI and high‑performance computing workloads. This solution works seamlessly with solid rear doors, bottom panels, air dams, and snap‑in filler panels for a complete containment strategy. Constructed from lightweight aluminum panels with a durable plastic seal, the duct offers long‑term reliability in demanding environments. Available in black or Glacier White finishes, it matches the aesthetic of most ZetaFrame® cabinet installations while delivering robust performance. Installation hardware is included, enabling rapid deployment without specialized tools. The vertical exhaust duct contributes to reduced cooling costs by improving airflow management, a key benefit for hyperscale and multi‑tenant data centers. Its modular two‑piece design allows technicians to adjust height on site, simplifying retrofits and future upgrades. CPI's global network of distributors ensures rapid access to replacement parts and expert support. Selecting this cabinet duct aligns with CPI's commitment to quality, rapid customization, and worldwide availability. Engineers can download the full spec sheet and user manual for detailed integration guidance. For tailored solutions, contact a CPI sales specialist to ensure the exhaust duct meets the specific requirements of your data‑center infrastructure.</p>"},{"primaryId":"39873-702","Primary ID":"39873-702","Color":"Black","Marketing Product Category ":"Cabinets & Enclosures","Marketing Product Family/Group":"Accessories","Marketing Product Subgroup":"Thermal Management","Marketing Product Series":"Vertical Exhaust Duct For ZetaFrame Cabinet","Marketing Description - Global English":"Vertical Exhaust Duct For ZetaFrame®Cabinet; For 29.5\"W (750 mm) x 41.3\"D (1050 mm) - 47.2\"D (1200 mm) Cabinet; 15”H-20”H (381 mm – 508 mm); One Cable Opening; Black","Shipping Weight":19,"Shipping Weight Uom":"LB","Ship Height":6,"Ship Height Uom":"in","Ship Length/Depth":114,"Ship Length/Depth Uom":"in","Ship Width":24,"Ship Width Uom":"in","Shipping Weight (Metric)":8.62,"Shipping Weight Uom (Metric)":"kg","Shipping Height (Metric)":15,"Shipping Height Uom (Metric)":"cm","Shipping Width (Metric)":61,"Shipping Width Uom (Metric)":"cm","Msrp $ Usd":875.26,"Country Of Origin":"US","Certifications":["Not Applicable"],"Series Level Manual Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/a8d9feb5/66eca50606cc930019d6bbd2/ZETAFRAME_USER_MANUAL"],"Series Level Installation Instructions Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/c35d59b5/66eca58f06cc930019d6c0f8/39873_IIS"],"Promote on Website":"1","Attached to Series":"1","Height":"20\" (508 mm)","Width":"25.8\" (655 mm)","Depth":"23.6\" (599 mm)","Cabinet Width":"29.5\"W (750 mm)","Duct Height":"15”-20”H (381 mm – 508 mm)","BABA Compliant":"1","Product Height":20,"Product Height Uom":"\"","Product Length/Depth":23.6,"Product Length/Depth Uom":"\"","Product Width ":25.8,"Product Width Uom":"\"","Product Height (Metric)":508,"Product Height Uom (Metric)":"mm","Product Depth (Metric)":599,"Product Depth Uom (Metric)":"mm","Product Width (Metric)":655,"Product Width Uom (Metric)":"mm","Product Weight":16.6,"Product Weight UOM":"LB","Short Description":"VED,750W,15-20IN H,BK","Search Terms":"39873-702,Vertical Exhaust Duct For ZetaFrame Cabinet,ZetaFrame Vertical Exhaust Duct For ZetaFrame Cabinet,Server cabinet Vertical Exhaust Duct For ZetaFrame Cabinet,Rack-mounted Vertical Exhaust Duct For ZetaFrame Cabinet,Data center Vertical Exhaust Duct For ZetaFrame Cabinet,Cabinet Vertical Exhaust Duct For ZetaFrame Cabinet solution,Network rack Vertical Exhaust Duct For ZetaFrame Cabinet,Structured cabling solution for Vertical Exhaust Duct For ZetaFrame Cabinet,Best Vertical Exhaust Duct For ZetaFrame Cabinet for server racks,How to organize cables with Vertical Exhaust Duct For ZetaFrame Cabinet,Efficient routing for Vertical Exhaust Duct For ZetaFrame Cabinet,Front-to-back cable routing for Vertical Exhaust Duct For ZetaFrame Cabinet,High-density cable organization for Vertical Exhaust Duct For ZetaFrame Cabinet,Professional cable management for Vertical Exhaust Duct For ZetaFrame Cabinet","Search Relevancy":2,"SKU Level SEO Page Title":"Vertical Exhaust Cabinet Duct - ZetaFrame® 39873-702 | Chatsworth","SKU Level SEO Meta Description":"Improve airflow with a cabinet duct that creates a sealed exhaust cabinet path for ZetaFrame® cabinets. Reduce cooling costs and ease cable entry.","SKU Level Web H4 Heading":"Sealed Airflow Path and Adjustable Height","SKU Level Web Paragraph Text":"<p>The vertical cabinet duct provides a dedicated, sealed pathway for hot air to leave the top of a ZetaFrame® enclosure, ensuring reliable airflow management. By directing exhaust directly to an overhead drop ceiling, it eliminates recirculation and supports consistent cooling performance. This solution is essential for data centers that demand high‑density equipment operation. Designed for cabinets with a depth of 41.3″ (1050 mm) or greater, the duct adjusts in height from 15″ to 20″ (381 mm‑508 mm) to match the space between the cabinet roof and the ceiling. The two‑piece construction allows quick installation and fine‑tuning without tools, accommodating variations in ceiling height. Compatibility with solid rear doors, bottom panels, and air directors creates a complete exhaust cabinet system. A brush‑sealed cable opening on the rear of the duct permits power and data cords to pass while maintaining the sealed airflow path. The flexible top seal conforms to uneven ceiling tiles, preserving the integrity of the exhaust cabinet design. This feature reduces the need for additional grommets or penetrations, simplifying cable management. The duct is fabricated from extruded aluminum panels with plastic corners and a durable black finish, offering corrosion resistance and a sleek appearance. An optional Glacier White finish is available to match cabinet aesthetics. The lightweight construction eases handling during installation while retaining structural strength. Implementing this vertical exhaust duct helps lower cooling costs by improving heat removal efficiency and supporting higher equipment density. It also enhances overall system reliability by preventing hot spots and supporting regulatory compliance for airflow containment. CPI's engineering expertise ensures the product integrates seamlessly with existing ZetaFrame® cabinets and data‑center architectures.</p>"},{"primaryId":"39873-703","Primary ID":"39873-703","Color":"Black","Marketing Product Category ":"Cabinets & Enclosures","Marketing Product Family/Group":"Accessories","Marketing Product Subgroup":"Thermal Management","Marketing Product Series":"Vertical Exhaust Duct For ZetaFrame Cabinet","Marketing Description - Global English":"Vertical Exhaust Duct For ZetaFrame®Cabinet; For 31.5\"W (800 mm) x 41.3\"D (1050 mm) - 47.2\"D (1200 mm) Cabinet; 15”H-20”H (381 mm – 508 mm); One Cable Opening; Black","Shipping Weight":20,"Shipping Weight Uom":"LB","Ship Height":6,"Ship Height Uom":"in","Ship Length/Depth":114,"Ship Length/Depth Uom":"in","Ship Width":24,"Ship Width Uom":"in","Shipping Weight (Metric)":9.07,"Shipping Weight Uom (Metric)":"kg","Shipping Height (Metric)":15,"Shipping Height Uom (Metric)":"cm","Shipping Width (Metric)":61,"Shipping Width Uom (Metric)":"cm","Msrp $ Usd":870.61,"Country Of Origin":"US","Certifications":["Not Applicable"],"Series Level Manual Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/a8d9feb5/66eca50606cc930019d6bbd2/ZETAFRAME_USER_MANUAL"],"Series Level Installation Instructions Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/c35d59b5/66eca58f06cc930019d6c0f8/39873_IIS"],"Promote on Website":"1","Attached to Series":"1","Height":"20\" (508 mm)","Width":"27.9\" (709 mm)","Depth":"23.6\" (599 mm)","Cabinet Width":"31.5\"W (800 mm)","Duct Height":"15”-20”H (381 mm – 508 mm)","BABA Compliant":"1","Product Height":20,"Product Height Uom":"\"","Product Length/Depth":23.6,"Product Length/Depth Uom":"\"","Product Width ":27.9,"Product Width Uom":"\"","Product Height (Metric)":508,"Product Height Uom (Metric)":"mm","Product Depth (Metric)":599,"Product Depth Uom (Metric)":"mm","Product Width (Metric)":709,"Product Width Uom (Metric)":"mm","Product Weight":17.3,"Product Weight UOM":"LB","Short Description":"VED,800W,15-20IN H,BK","Search Terms":"39873-703,Vertical Exhaust Duct For ZetaFrame Cabinet,ZetaFrame Vertical Exhaust Duct For ZetaFrame Cabinet,Server cabinet Vertical Exhaust Duct For ZetaFrame Cabinet,Rack-mounted Vertical Exhaust Duct For ZetaFrame Cabinet,Data center Vertical Exhaust Duct For ZetaFrame Cabinet,Cabinet Vertical Exhaust Duct For ZetaFrame Cabinet solution,Network rack Vertical Exhaust Duct For ZetaFrame Cabinet,Structured cabling solution for Vertical Exhaust Duct For ZetaFrame Cabinet,Best Vertical Exhaust Duct For ZetaFrame Cabinet for server racks,How to organize cables with Vertical Exhaust Duct For ZetaFrame Cabinet,Efficient routing for Vertical Exhaust Duct For ZetaFrame Cabinet,Front-to-back cable routing for Vertical Exhaust Duct For ZetaFrame Cabinet,High-density cable organization for Vertical Exhaust Duct For ZetaFrame Cabinet,Professional cable management for Vertical Exhaust Duct For ZetaFrame Cabinet","Search Relevancy":2,"SKU Level SEO Page Title":"39873-703 Vertical Exhaust Duct for ZetaFrame® - Thermal Cabinet | Chatsworth","SKU Level SEO Meta Description":"Improve airflow and reduce cooling costs with the vertical exhaust duct for ZetaFrame® cabinets. Engineered for integration in a thermal cabinet solution.","SKU Level Web H4 Heading":"Key Benefits and Installation Features of the Vertical Exhaust Duct","SKU Level Web Paragraph Text":"<p>The vertical exhaust duct provides a sealed pathway for hot air to exit the top of a thermal cabinet, ensuring that exhaust air is directed toward an overhead drop ceiling. By creating a closed-loop airflow system, it minimizes recirculation and helps maintain consistent temperatures across equipment. This design is essential for data center environments where precise thermal management is critical for reliability.</p>"},{"primaryId":"39873-704","Primary ID":"39873-704","Color":"Black","Marketing Product Category ":"Cabinets & Enclosures","Marketing Product Family/Group":"Accessories","Marketing Product Subgroup":"Thermal Management","Marketing Product Series":"Vertical Exhaust Duct For ZetaFrame Cabinet","Marketing Description - Global English":"Vertical Exhaust Duct For ZetaFrame®Cabinet; For 23.6\"W (600 mm) x 41.3\"D (1050 mm) - 47.2\"D (1200 mm) Cabinet; 20”H-34”H (508 mm – 863 mm); One Cable Opening; Black","Shipping Weight":26,"Shipping Weight Uom":"LB","Ship Height":6,"Ship Height Uom":"in","Ship Length/Depth":114,"Ship Length/Depth Uom":"in","Ship Width":24,"Ship Width Uom":"in","Shipping Weight (Metric)":11.79,"Shipping Weight Uom (Metric)":"kg","Shipping Height (Metric)":15,"Shipping Height Uom (Metric)":"cm","Shipping Width (Metric)":61,"Shipping Width Uom (Metric)":"cm","Msrp $ Usd":877.59,"Country Of Origin":"US","Certifications":["Not Applicable"],"Series Level Manual Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/a8d9feb5/66eca50606cc930019d6bbd2/ZETAFRAME_USER_MANUAL"],"Series Level Installation Instructions Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/c35d59b5/66eca58f06cc930019d6c0f8/39873_IIS"],"Promote on Website":"1","Attached to Series":"1","Height":"34\" (863.6 mm)","Width":"19.9\" (505 mm)","Depth":"23.6\" (599 mm)","Cabinet Width":"23.6\"W (600 mm)","Duct Height":"20”-34”H (508 mm – 863 mm)","BABA Compliant":"1","Product Height":34,"Product Height Uom":"\"","Product Length/Depth":23.6,"Product Length/Depth Uom":"\"","Product Width ":19.9,"Product Width Uom":"\"","Product Height (Metric)":864,"Product Height Uom (Metric)":"mm","Product Depth (Metric)":599,"Product Depth Uom (Metric)":"mm","Product Width (Metric)":505,"Product Width Uom (Metric)":"mm","Product Weight":23.4,"Product Weight UOM":"LB","Short Description":"VED,600W,20-34H","Search Terms":"39873-704,Vertical Exhaust Duct For ZetaFrame Cabinet,ZetaFrame Vertical Exhaust Duct For ZetaFrame Cabinet,Server cabinet Vertical Exhaust Duct For ZetaFrame Cabinet,Rack-mounted Vertical Exhaust Duct For ZetaFrame Cabinet,Data center Vertical Exhaust Duct For ZetaFrame Cabinet,Cabinet Vertical Exhaust Duct For ZetaFrame Cabinet solution,Network rack Vertical Exhaust Duct For ZetaFrame Cabinet,Structured cabling solution for Vertical Exhaust Duct For ZetaFrame Cabinet,Best Vertical Exhaust Duct For ZetaFrame Cabinet for server racks,How to organize cables with Vertical Exhaust Duct For ZetaFrame Cabinet,Efficient routing for Vertical Exhaust Duct For ZetaFrame Cabinet,Front-to-back cable routing for Vertical Exhaust Duct For ZetaFrame Cabinet,High-density cable organization for Vertical Exhaust Duct For ZetaFrame Cabinet,Professional cable management for Vertical Exhaust Duct For ZetaFrame Cabinet","Search Relevancy":2,"SKU Level SEO Page Title":"Exhaust Duct for ZetaFrame® Cabinet - Cabinet Exhaust | Chatsworth","SKU Level SEO Meta Description":"Improve airflow with the ZetaFrame® vertical exhaust duct, delivering reliable cabinet exhaust for high‑density data centers. Boost cooling efficiency.","SKU Level Web H4 Heading":"Key Features of the Vertical Exhaust Duct","SKU Level Web Paragraph Text":"<p>Exhaust cabinets require a sealed pathway to move hot air efficiently, and the vertical exhaust duct provides that essential channel for ZetaFrame® enclosures. Designed for high‑density data center environments, the duct integrates seamlessly with existing airflow containment strategies. Its robust aluminum construction ensures long‑term durability while maintaining a sleek black finish.</p>"},{"primaryId":"39873-705","Primary ID":"39873-705","Color":"Black","Marketing Product Category ":"Cabinets & Enclosures","Marketing Product Family/Group":"Accessories","Marketing Product Subgroup":"Thermal Management","Marketing Product Series":"Vertical Exhaust Duct For ZetaFrame Cabinet","Marketing Description - Global English":"Vertical Exhaust Duct For ZetaFrame®Cabinet; For 27.6\"W (700 mm) x 41.3\"D (1050 mm) - 47.2\"D (1200 mm) Cabinet; 20”H-34”H (508 mm – 863 mm); One Cable Opening; Black","Shipping Weight":27,"Shipping Weight Uom":"LB","Ship Height":6,"Ship Height Uom":"in","Ship Length/Depth":114,"Ship Length/Depth Uom":"in","Ship Width":24,"Ship Width Uom":"in","Shipping Weight (Metric)":12.25,"Shipping Weight Uom (Metric)":"kg","Shipping Height (Metric)":15,"Shipping Height Uom (Metric)":"cm","Shipping Width (Metric)":61,"Shipping Width Uom (Metric)":"cm","Msrp $ Usd":956.74,"Country Of Origin":"US","Certifications":["Not Applicable"],"Series Level Manual Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/a8d9feb5/66eca50606cc930019d6bbd2/ZETAFRAME_USER_MANUAL"],"Series Level Installation Instructions Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/c35d59b5/66eca58f06cc930019d6c0f8/39873_IIS"],"Promote on Website":"1","Attached to Series":"1","Height":"34\" (863.6 mm)","Width":"23.8\" (605 mm)","Depth":"23.6\" (599 mm)","Cabinet Width":"27.6\"W (700 mm)","Duct Height":"20”-34”H (508 mm – 863 mm)","BABA Compliant":"1","Product Height":34,"Product Height Uom":"\"","Product Length/Depth":23.6,"Product Length/Depth Uom":"\"","Product Width ":23.8,"Product Width Uom":"\"","Product Height (Metric)":864,"Product Height Uom (Metric)":"mm","Product Depth (Metric)":599,"Product Depth Uom (Metric)":"mm","Product Width (Metric)":605,"Product Width Uom (Metric)":"mm","Product Weight":23.7,"Product Weight UOM":"LB","Short Description":"VED,700W,20-34H","Search Terms":"39873-705,Vertical Exhaust Duct For ZetaFrame Cabinet,ZetaFrame Vertical Exhaust Duct For ZetaFrame Cabinet,Server cabinet Vertical Exhaust Duct For ZetaFrame Cabinet,Rack-mounted Vertical Exhaust Duct For ZetaFrame Cabinet,Data center Vertical Exhaust Duct For ZetaFrame Cabinet,Cabinet Vertical Exhaust Duct For ZetaFrame Cabinet solution,Network rack Vertical Exhaust Duct For ZetaFrame Cabinet,Structured cabling solution for Vertical Exhaust Duct For ZetaFrame Cabinet,Best Vertical Exhaust Duct For ZetaFrame Cabinet for server racks,How to organize cables with Vertical Exhaust Duct For ZetaFrame Cabinet,Efficient routing for Vertical Exhaust Duct For ZetaFrame Cabinet,Front-to-back cable routing for Vertical Exhaust Duct For ZetaFrame Cabinet,High-density cable organization for Vertical Exhaust Duct For ZetaFrame Cabinet,Professional cable management for Vertical Exhaust Duct For ZetaFrame Cabinet","Search Relevancy":2,"SKU Level SEO Page Title":"Vertical Exhaust Duct for ZetaFrame Cabinet | Chatsworth","SKU Level SEO Meta Description":"Enhance data center cooling with the Vertical Exhaust Duct for ZetaFrame cabinets. This cabinet exhaust solution provides a sealed pathway for hot air return, improving thermal management efficiency. Learn more.","SKU Level Web H4 Heading":"Integrating Vertical Exhaust Ducts into Exhaust Cabinet Systems","SKU Level Web Paragraph Text":"<p>The Vertical Exhaust Duct from Chatsworth Products (CPI) is an essential accessory for ZetaFrame® cabinets, designed to create a sealed pathway for exhaust air management. This cabinet exhaust solution directs hot air from the top of the cabinet to an overhead drop ceiling, integral to a closed hot air return system. By efficiently handling cabinet exhaust, it significantly improves thermal efficiency in data centers.</p><p>Key features of this vertical exhaust duct include adjustable height from 20 to 34 inches and a flexible top seal that adapts to ceiling variations. The integrated brush-sealed cable opening on the back allows for power cord entry while maintaining airflow integrity. This design works seamlessly with other thermal management accessories like solid rear doors and air dams for comprehensive containment.</p><p>For exhaust cabinet systems, this duct is compatible with ZetaFrame cabinets measuring 41.3 inches deep or deeper, facilitating a robust thermal strategy. The two-piece construction enables easy installation and adjustment, ensuring a perfect fit between cabinet and ceiling. This results in enhanced cooling performance and reduced operational costs for data centers.</p><p>The cable opening feature functions as an effective cabinet cable duct, providing a secure path for power cords without disrupting the sealed environment. This ensures that both airflow and cable management are optimized, preventing hot spots and maintaining system reliability. It is a critical component for maintaining clean and efficient data center layouts.</p><p>Overall, the Vertical Exhaust Duct enhances exhaust cabinet configurations by supporting high-density applications and future-ready data centers. CPI's expertise in thermal management ensures that this solution meets the demands of AI, HPC, and liquid cooling technologies. With rapid customization and global support, CPI empowers enterprises to achieve superior operational efficiency.</p>"},{"primaryId":"39873-706","Primary ID":"39873-706","Color":"Black","Marketing Product Category ":"Cabinets & Enclosures","Marketing Product Family/Group":"Accessories","Marketing Product Subgroup":"Thermal Management","Marketing Product Series":"Vertical Exhaust Duct For ZetaFrame Cabinet","Marketing Description - Global English":"Vertical Exhaust Duct For ZetaFrame®Cabinet; For 29.5\"W (750 mm) x 41.3\"D (1050 mm) - 47.2\"D (1200 mm) Cabinet; 20”H-34”H (508 mm – 863 mm); One Cable Opening; Black","Shipping Weight":28,"Shipping Weight Uom":"LB","Ship Height":6,"Ship Height Uom":"in","Ship Length/Depth":114,"Ship Length/Depth Uom":"in","Ship Width":24,"Ship Width Uom":"in","Shipping Weight (Metric)":12.7,"Shipping Weight Uom (Metric)":"kg","Shipping Height (Metric)":15,"Shipping Height Uom (Metric)":"cm","Shipping Width (Metric)":61,"Shipping Width Uom (Metric)":"cm","Msrp $ Usd":956.74,"Country Of Origin":"US","Certifications":["Not Applicable"],"Series Level Manual Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/a8d9feb5/66eca50606cc930019d6bbd2/ZETAFRAME_USER_MANUAL"],"Series Level Installation Instructions Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/c35d59b5/66eca58f06cc930019d6c0f8/39873_IIS"],"Promote on Website":"1","Attached to Series":"1","Height":"34\" (863.6 mm)","Width":"25.8\" (655 mm)","Depth":"23.6\" (599 mm)","Cabinet Width":"29.5\"W (750 mm)","Duct Height":"20”-34”H (508 mm – 863 mm)","BABA Compliant":"1","Product Height":34,"Product Height Uom":"\"","Product Length/Depth":23.6,"Product Length/Depth Uom":"\"","Product Width ":25.8,"Product Width Uom":"\"","Product Height (Metric)":864,"Product Height Uom (Metric)":"mm","Product Depth (Metric)":599,"Product Depth Uom (Metric)":"mm","Product Width (Metric)":655,"Product Width Uom (Metric)":"mm","Product Weight":24.6,"Product Weight UOM":"LB","Short Description":"VED,750W,20-34H","Search Terms":"39873-706,Vertical Exhaust Duct For ZetaFrame Cabinet,ZetaFrame Vertical Exhaust Duct For ZetaFrame Cabinet,Server cabinet Vertical Exhaust Duct For ZetaFrame Cabinet,Rack-mounted Vertical Exhaust Duct For ZetaFrame Cabinet,Data center Vertical Exhaust Duct For ZetaFrame Cabinet,Cabinet Vertical Exhaust Duct For ZetaFrame Cabinet solution,Network rack Vertical Exhaust Duct For ZetaFrame Cabinet,Structured cabling solution for Vertical Exhaust Duct For ZetaFrame Cabinet,Best Vertical Exhaust Duct For ZetaFrame Cabinet for server racks,How to organize cables with Vertical Exhaust Duct For ZetaFrame Cabinet,Efficient routing for Vertical Exhaust Duct For ZetaFrame Cabinet,Front-to-back cable routing for Vertical Exhaust Duct For ZetaFrame Cabinet,High-density cable organization for Vertical Exhaust Duct For ZetaFrame Cabinet,Professional cable management for Vertical Exhaust Duct For ZetaFrame Cabinet","Search Relevancy":2},{"primaryId":"39873-707","Primary ID":"39873-707","Color":"Black","Marketing Product Category ":"Cabinets & Enclosures","Marketing Product Family/Group":"Accessories","Marketing Product Subgroup":"Thermal Management","Marketing Product Series":"Vertical Exhaust Duct For ZetaFrame Cabinet","Marketing Description - Global English":"Vertical Exhaust Duct For ZetaFrame®Cabinet; For 31.5\"W (800 mm) x 41.3\"D (1050 mm) - 47.2\"D (1200 mm) Cabinet; 20”H-34”H (508 mm – 863 mm); One Cable Opening; Black","Shipping Weight":29,"Shipping Weight Uom":"LB","Ship Height":6,"Ship Height Uom":"in","Ship Length/Depth":114,"Ship Length/Depth Uom":"in","Ship Width":24,"Ship Width Uom":"in","Shipping Weight (Metric)":13.15,"Shipping Weight Uom (Metric)":"kg","Shipping Height (Metric)":15,"Shipping Height Uom (Metric)":"cm","Shipping Width (Metric)":61,"Shipping Width Uom (Metric)":"cm","Msrp $ Usd":952.08,"Country Of Origin":"US","Certifications":["Not Applicable"],"Series Level Manual Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/a8d9feb5/66eca50606cc930019d6bbd2/ZETAFRAME_USER_MANUAL"],"Series Level Installation Instructions Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/c35d59b5/66eca58f06cc930019d6c0f8/39873_IIS"],"Promote on Website":"1","Attached to Series":"1","Height":"34\" (863.6 mm)","Width":"27.9\" (709 mm)","Depth":"23.6\" (599 mm)","Cabinet Width":"31.5\"W (800 mm)","Duct Height":"20”-34”H (508 mm – 863 mm)","BABA Compliant":"1","Product Height":34,"Product Height Uom":"\"","Product Length/Depth":23.6,"Product Length/Depth Uom":"\"","Product Width ":27.9,"Product Width Uom":"\"","Product Height (Metric)":864,"Product Height Uom (Metric)":"mm","Product Depth (Metric)":599,"Product Depth Uom (Metric)":"mm","Product Width (Metric)":709,"Product Width Uom (Metric)":"mm","Product Weight":25.7,"Product Weight UOM":"LB","Short Description":"VED,800W,20-34H","Search Terms":"39873-707,Vertical Exhaust Duct For ZetaFrame Cabinet,ZetaFrame Vertical Exhaust Duct For ZetaFrame Cabinet,Server cabinet Vertical Exhaust Duct For ZetaFrame Cabinet,Rack-mounted Vertical Exhaust Duct For ZetaFrame Cabinet,Data center Vertical Exhaust Duct For ZetaFrame Cabinet,Cabinet Vertical Exhaust Duct For ZetaFrame Cabinet solution,Network rack Vertical Exhaust Duct For ZetaFrame Cabinet,Structured cabling solution for Vertical Exhaust Duct For ZetaFrame Cabinet,Best Vertical Exhaust Duct For ZetaFrame Cabinet for server racks,How to organize cables with Vertical Exhaust Duct For ZetaFrame Cabinet,Efficient routing for Vertical Exhaust Duct For ZetaFrame Cabinet,Front-to-back cable routing for Vertical Exhaust Duct For ZetaFrame Cabinet,High-density cable organization for Vertical Exhaust Duct For ZetaFrame Cabinet,Professional cable management for Vertical Exhaust Duct For ZetaFrame Cabinet","Search Relevancy":2},{"primaryId":"39873-708","Primary ID":"39873-708","Color":"Black","Marketing Product Category ":"Cabinets & Enclosures","Marketing Product Family/Group":"Accessories","Marketing Product Subgroup":"Thermal Management","Marketing Product Series":"Vertical Exhaust Duct For ZetaFrame Cabinet","Marketing Description - Global English":"Vertical Exhaust Duct For ZetaFrame®Cabinet; For 23.6\"W (600 mm) x 41.3\"D (1050 mm) - 47.2\"D (1200 mm) Cabinet; 34”H-60”H (863 mm – 1523 mm); One Cable Opening; Black","Shipping Weight":44,"Shipping Weight Uom":"LB","Ship Height":6,"Ship Height Uom":"in","Ship Length/Depth":114,"Ship Length/Depth Uom":"in","Ship Width":37,"Ship Width Uom":"in","Shipping Weight (Metric)":19.96,"Shipping Weight Uom (Metric)":"kg","Shipping Height (Metric)":15,"Shipping Height Uom (Metric)":"cm","Shipping Width (Metric)":94,"Shipping Width Uom (Metric)":"cm","Msrp $ Usd":1289.62,"Country Of Origin":"US","Certifications":["Not Applicable"],"Series Level Manual Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/a8d9feb5/66eca50606cc930019d6bbd2/ZETAFRAME_USER_MANUAL"],"Series Level Installation Instructions Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/c35d59b5/66eca58f06cc930019d6c0f8/39873_IIS"],"Promote on Website":"1","Attached to Series":"1","Height":"60\" (1524 mm)","Width":"19.9\" (505 mm)","Depth":"23.6\" (599 mm)","Cabinet Width":"23.6\"W (600 mm)","Duct Height":"34”-60”H (863 mm – 1523 mm)","BABA Compliant":"1","Product Height":60,"Product Height Uom":"\"","Product Length/Depth":23.6,"Product Length/Depth Uom":"\"","Product Width ":19.9,"Product Width Uom":"\"","Product Height (Metric)":1524,"Product Height Uom (Metric)":"mm","Product Depth (Metric)":599,"Product Depth Uom (Metric)":"mm","Product Width (Metric)":505,"Product Width Uom (Metric)":"mm","Product Weight":38.7,"Product Weight UOM":"LB","Short Description":"VED,600W,34-60H","Search Terms":"39873-708,Vertical Exhaust Duct For ZetaFrame Cabinet,ZetaFrame Vertical Exhaust Duct For ZetaFrame Cabinet,Server cabinet Vertical Exhaust Duct For ZetaFrame Cabinet,Rack-mounted Vertical Exhaust Duct For ZetaFrame Cabinet,Data center Vertical Exhaust Duct For ZetaFrame Cabinet,Cabinet Vertical Exhaust Duct For ZetaFrame Cabinet solution,Network rack Vertical Exhaust Duct For ZetaFrame Cabinet,Structured cabling solution for Vertical Exhaust Duct For ZetaFrame Cabinet,Best Vertical Exhaust Duct For ZetaFrame Cabinet for server racks,How to organize cables with Vertical Exhaust Duct For ZetaFrame Cabinet,Efficient routing for Vertical Exhaust Duct For ZetaFrame Cabinet,Front-to-back cable routing for Vertical Exhaust Duct For ZetaFrame Cabinet,High-density cable organization for Vertical Exhaust Duct For ZetaFrame Cabinet,Professional cable management for Vertical Exhaust Duct For ZetaFrame Cabinet","Search Relevancy":2,"SKU Level SEO Page Title":"Vertical Exhaust Duct for ZetaFrame Cabinet | Chatsworth","SKU Level SEO Meta Description":"CPI's vertical exhaust duct enhances cabinet exhaust management for ZetaFrame systems. Improve airflow containment and reduce cooling costs with efficient thermal solutions.","SKU Level Web H4 Heading":"Optimize Airflow with Vertical Exhaust Duct Systems","SKU Level Web Paragraph Text":"<p>The Vertical Exhaust Duct for ZetaFrame® Cabinet provides a sealed pathway for exhaust air, directing it to an overhead drop ceiling as part of a closed hot air return system. This vertical exhaust solution ensures efficient thermal management by preventing hot air recirculation in data center environments. It is designed for cabinets measuring 23.6 inches wide (600 mm) and depths from 41.3 inches to 47.2 inches (1050 mm to 1200 mm), with adjustable heights from 34 inches to 60 inches (863 mm to 1523 mm).</p><p>Engineered for compatibility with solid rear doors, bottom panels, and air dams, this duct supports a complete airflow containment strategy to maximize cooling efficiency. The two-piece design allows easy height adjustment, while a flexible top seal accommodates variations in drop ceilings for reliable performance. A brush-sealed cable opening on the back facilitates power cord entry, maintaining seal integrity without compromising accessibility.</p><p>Constructed from durable aluminum with black plastic seals and corners, this vertical exhaust duct offers long-lasting reliability in demanding applications. Its black finish blends seamlessly with CPI cabinet systems, ensuring a professional appearance while enhancing cabinet exhaust management. This accessory is essential for data centers seeking to reduce energy costs and improve equipment uptime through optimized thermal control.</p><p>Ideal for use in enterprise, hyperscale, and colocation data centers, this exhaust duct addresses the challenges of high-density computing and AI workloads. By integrating with CPI's comprehensive thermal management solutions, it helps maintain stable operating temperatures and extends equipment lifespan. The vertical exhaust design is a key component in achieving regulatory compliance and future-ready infrastructure.</p><p>For expert guidance on implementing this and other exhaust management solutions, consult CPI's team of specialists. With decades of experience in data center infrastructure, CPI delivers customized support to meet your specific thermal needs. Explore more resources, including CAD blocks and BIM drawings, to streamline your deployment process.</p>"},{"primaryId":"39873-709","Primary ID":"39873-709","Color":"Black","Marketing Product Category ":"Cabinets & Enclosures","Marketing Product Family/Group":"Accessories","Marketing Product Subgroup":"Thermal Management","Marketing Product Series":"Vertical Exhaust Duct For ZetaFrame Cabinet","Marketing Description - Global English":"Vertical Exhaust Duct For ZetaFrame®Cabinet; For 27.6\"W (700 mm) x 41.3\"D (1050 mm) - 47.2\"D (1200 mm) Cabinet; 34”H-60”H (863 mm – 1523 mm); One Cable Opening; Black","Shipping Weight":47,"Shipping Weight Uom":"LB","Ship Height":6,"Ship Height Uom":"in","Ship Length/Depth":114,"Ship Length/Depth Uom":"in","Ship Width":37,"Ship Width Uom":"in","Shipping Weight (Metric)":21.32,"Shipping Weight Uom (Metric)":"kg","Shipping Height (Metric)":15,"Shipping Height Uom (Metric)":"cm","Shipping Width (Metric)":94,"Shipping Width Uom (Metric)":"cm","Msrp $ Usd":1294.27,"Country Of Origin":"US","Certifications":["Not Applicable"],"Series Level Manual Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/a8d9feb5/66eca50606cc930019d6bbd2/ZETAFRAME_USER_MANUAL"],"Series Level Installation Instructions Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/c35d59b5/66eca58f06cc930019d6c0f8/39873_IIS"],"Promote on Website":"1","Attached to Series":"1","Height":"60\" (1524 mm)","Width":"23.8\" (605 mm)","Depth":"23.6\" (599 mm)","Cabinet Width":"27.6\"W (700 mm)","Duct Height":"34”-60”H (863 mm – 1523 mm)","BABA Compliant":"1","Product Height":60,"Product Height Uom":"\"","Product Length/Depth":23.6,"Product Length/Depth Uom":"\"","Product Width ":23.8,"Product Width Uom":"\"","Product Height (Metric)":1524,"Product Height Uom (Metric)":"mm","Product Depth (Metric)":599,"Product Depth Uom (Metric)":"mm","Product Width (Metric)":605,"Product Width Uom (Metric)":"mm","Product Weight":39,"Product Weight UOM":"LB","Short Description":"VED,700W,34-60H","Search Terms":"39873-709,Vertical Exhaust Duct For ZetaFrame Cabinet,ZetaFrame Vertical Exhaust Duct For ZetaFrame Cabinet,Server cabinet Vertical Exhaust Duct For ZetaFrame Cabinet,Rack-mounted Vertical Exhaust Duct For ZetaFrame Cabinet,Data center Vertical Exhaust Duct For ZetaFrame Cabinet,Cabinet Vertical Exhaust Duct For ZetaFrame Cabinet solution,Network rack Vertical Exhaust Duct For ZetaFrame Cabinet,Structured cabling solution for Vertical Exhaust Duct For ZetaFrame Cabinet,Best Vertical Exhaust Duct For ZetaFrame Cabinet for server racks,How to organize cables with Vertical Exhaust Duct For ZetaFrame Cabinet,Efficient routing for Vertical Exhaust Duct For ZetaFrame Cabinet,Front-to-back cable routing for Vertical Exhaust Duct For ZetaFrame Cabinet,High-density cable organization for Vertical Exhaust Duct For ZetaFrame Cabinet,Professional cable management for Vertical Exhaust Duct For ZetaFrame Cabinet","Search Relevancy":2,"SKU Level SEO Page Title":"Exhaust Cabinets - ZetaFrame® Cabinet Duct | Chatsworth","SKU Level SEO Meta Description":"Optimize airflow with the 39873-709 vertical exhaust duct for ZetaFrame® cabinets. Ideal for exhaust cabinets and cabinet duct integration. Learn more.","SKU Level Web H4 Heading":"Key Features of the Vertical Exhaust Duct","SKU Level Web Paragraph Text":"<p>The 39873-709 vertical exhaust duct provides a sealed pathway for hot air to exit the top of a ZetaFrame® cabinet. Designed for cabinets 27.6 in (700 mm) wide and up to 60 in (1523 mm) high, the duct aligns with overhead drop ceilings for efficient airflow. This solution supports exhaust cabinets by maintaining a closed hot‑air return loop. The two‑piece construction allows height adjustment in three increments to span the distance between the cabinet roof and ceiling. A flexible top seal accommodates variations in ceiling height while preserving a tight seal. The integrated brush‑sealed cable opening enables power cords to pass without compromising airflow. The duct pairs with solid rear doors, bottom panels, air dams, snap‑in filler panels and air directors for a complete airflow containment strategy. It is compatible with cabinet duct systems and cabinet cable ducts to maximize cooling efficiency. Installation hardware is included, simplifying the duct installation center point process. Constructed from aluminum panels with plastic corners and a durable black finish, the duct meets rigorous data‑center durability standards. An optional Glacier White finish is available to match aesthetic requirements. All components are UL listed and designed for long‑term service in high‑density environments. By directing exhaust air directly to the building's HVAC system, the vertical exhaust duct reduces cooling costs and improves overall data‑center efficiency. CPI's global network of distributors provides rapid customization and technical support for seamless deployment. Engineers can use the CPI Product Designer tool to verify fit‑for‑purpose integration with existing ZetaFrame® enclosures.</p>"},{"primaryId":"39873-710","Primary ID":"39873-710","Color":"Black","Marketing Product Category ":"Cabinets & Enclosures","Marketing Product Family/Group":"Accessories","Marketing Product Subgroup":"Thermal Management","Marketing Product Series":"Vertical Exhaust Duct For ZetaFrame Cabinet","Marketing Description - Global English":"Vertical Exhaust Duct For ZetaFrame®Cabinet; For 29.5\"W (750 mm) x 41.3\"D (1050 mm) - 47.2\"D (1200 mm) Cabinet; 34”H-60”H (863 mm – 1523 mm); One Cable Opening; Black","Shipping Weight":49,"Shipping Weight Uom":"LB","Ship Height":6,"Ship Height Uom":"in","Ship Length/Depth":114,"Ship Length/Depth Uom":"in","Ship Width":37,"Ship Width Uom":"in","Shipping Weight (Metric)":22.23,"Shipping Weight Uom (Metric)":"kg","Shipping Height (Metric)":15,"Shipping Height Uom (Metric)":"cm","Shipping Width (Metric)":94,"Shipping Width Uom (Metric)":"cm","Msrp $ Usd":1368.76,"Country Of Origin":"US","Certifications":["Not Applicable"],"Series Level Manual Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/a8d9feb5/66eca50606cc930019d6bbd2/ZETAFRAME_USER_MANUAL"],"Series Level Installation Instructions Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/c35d59b5/66eca58f06cc930019d6c0f8/39873_IIS"],"Promote on Website":"1","Attached to Series":"1","Height":"60\" (1524 mm)","Width":"25.8\" (655 mm)","Depth":"23.6\" (599 mm)","Cabinet Width":"29.5\"W (750 mm)","Duct Height":"34”-60”H (863 mm – 1523 mm)","BABA Compliant":"1","Product Height":60,"Product Height Uom":"\"","Product Length/Depth":23.6,"Product Length/Depth Uom":"\"","Product Width ":25.8,"Product Width Uom":"\"","Product Height (Metric)":1524,"Product Height Uom (Metric)":"mm","Product Depth (Metric)":599,"Product Depth Uom (Metric)":"mm","Product Width (Metric)":655,"Product Width Uom (Metric)":"mm","Product Weight":40.7,"Product Weight UOM":"LB","Short Description":"VED,750W,34-60H","Search Terms":"39873-710,Vertical Exhaust Duct For ZetaFrame Cabinet,ZetaFrame Vertical Exhaust Duct For ZetaFrame Cabinet,Server cabinet Vertical Exhaust Duct For ZetaFrame Cabinet,Rack-mounted Vertical Exhaust Duct For ZetaFrame Cabinet,Data center Vertical Exhaust Duct For ZetaFrame Cabinet,Cabinet Vertical Exhaust Duct For ZetaFrame Cabinet solution,Network rack Vertical Exhaust Duct For ZetaFrame Cabinet,Structured cabling solution for Vertical Exhaust Duct For ZetaFrame Cabinet,Best Vertical Exhaust Duct For ZetaFrame Cabinet for server racks,How to organize cables with Vertical Exhaust Duct For ZetaFrame Cabinet,Efficient routing for Vertical Exhaust Duct For ZetaFrame Cabinet,Front-to-back cable routing for Vertical Exhaust Duct For ZetaFrame Cabinet,High-density cable organization for Vertical Exhaust Duct For ZetaFrame Cabinet,Professional cable management for Vertical Exhaust Duct For ZetaFrame Cabinet","Search Relevancy":2,"SKU Level SEO Page Title":"Drop Ceiling Duct for ZetaFrame® Cabinet - 39873-710 | Chatsworth","SKU Level SEO Meta Description":"Secure data center airflow with a drop ceiling duct and overhead duct. Adjustable height, duct corners, and power duct accessories simplify installation.","SKU Level Web H4 Heading":"Duct Corners and Adjustable Height for Seamless Installation","SKU Level Web Paragraph Text":"<p>The drop ceiling duct provides a sealed pathway that channels warm air from the top of a ZetaFrame® cabinet to a drop ceiling air return. Designed for overhead duct configurations, it integrates easily with existing ceiling grids and maintains consistent airflow across the data center. This solution reduces hot spots and supports high‑density equipment deployments. Adjustable‑height sections allow the duct to span the distance between the cabinet roof and the ceiling, accommodating variations in ceiling height. Built‑in duct corners guide airflow around obstacles and preserve a smooth, low‑turbulence path. The flexible top seal adapts to minor ceiling irregularities while preserving a tight seal. Installation includes a brush‑sealed cable opening, enabling power and data cables to pass without compromising the sealed environment. The design is compatible with standard power duct accessories, simplifying routing of power cords and reducing clutter. All hardware is supplied with the kit, ensuring a quick, error‑free fit. The vertical exhaust duct matches the dimensions of ZetaFrame® cabinets that are 29.5″ W (750 mm) and 34″-60″ H (863 mm-1523 mm). Aluminum panels deliver durability, while the black or Glacier White finish blends with typical data center aesthetics. One‑piece construction minimizes part count and eases inventory management. By directing hot air directly to a drop ceiling duct, facilities achieve lower cooling costs and improved energy efficiency. CPI's expertise in thermal management ensures reliable performance in hyperscale, multitenant, and edge data center environments. The result is a clean, efficient airflow strategy that supports today's demanding IT workloads.</p>"},{"primaryId":"39873-711","Primary ID":"39873-711","Color":"Black","Marketing Product Category ":"Cabinets & Enclosures","Marketing Product Family/Group":"Accessories","Marketing Product Subgroup":"Thermal Management","Marketing Product Series":"Vertical Exhaust Duct For ZetaFrame Cabinet","Marketing Description - Global English":"Vertical Exhaust Duct For ZetaFrame®Cabinet; For 31.5\"W (800 mm) x 41.3\"D (1050 mm) - 47.2\"D (1200 mm) Cabinet; 34”H-60”H (863 mm – 1523 mm); One Cable Opening; Black","Shipping Weight":51,"Shipping Weight Uom":"LB","Ship Height":6,"Ship Height Uom":"in","Ship Length/Depth":114,"Ship Length/Depth Uom":"in","Ship Width":37,"Ship Width Uom":"in","Shipping Weight (Metric)":23.13,"Shipping Weight Uom (Metric)":"kg","Shipping Height (Metric)":15,"Shipping Height Uom (Metric)":"cm","Shipping Width (Metric)":94,"Shipping Width Uom (Metric)":"cm","Msrp $ Usd":1364.11,"Country Of Origin":"US","Certifications":["Not Applicable"],"Series Level Manual Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/a8d9feb5/66eca50606cc930019d6bbd2/ZETAFRAME_USER_MANUAL"],"Series Level Installation Instructions Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/c35d59b5/66eca58f06cc930019d6c0f8/39873_IIS"],"Promote on Website":"1","Attached to Series":"1","Height":"60\" (1524 mm)","Width":"27.9\" (709 mm)","Depth":"23.6\" (599 mm)","Cabinet Width":"31.5\"W (800 mm)","Duct Height":"34”-60”H (863 mm – 1523 mm)","BABA Compliant":"1","Product Height":60,"Product Height Uom":"\"","Product Length/Depth":23.6,"Product Length/Depth Uom":"\"","Product Width ":27.9,"Product Width Uom":"\"","Product Height (Metric)":1524,"Product Height Uom (Metric)":"mm","Product Depth (Metric)":599,"Product Depth Uom (Metric)":"mm","Product Width (Metric)":709,"Product Width Uom (Metric)":"mm","Product Weight":42.5,"Product Weight UOM":"LB","Short Description":"VED,800W,34-60H","Search Terms":"39873-711,Vertical Exhaust Duct For ZetaFrame Cabinet,ZetaFrame Vertical Exhaust Duct For ZetaFrame Cabinet,Server cabinet Vertical Exhaust Duct For ZetaFrame Cabinet,Rack-mounted Vertical Exhaust Duct For ZetaFrame Cabinet,Data center Vertical Exhaust Duct For ZetaFrame Cabinet,Cabinet Vertical Exhaust Duct For ZetaFrame Cabinet solution,Network rack Vertical Exhaust Duct For ZetaFrame Cabinet,Structured cabling solution for Vertical Exhaust Duct For ZetaFrame Cabinet,Best Vertical Exhaust Duct For ZetaFrame Cabinet for server racks,How to organize cables with Vertical Exhaust Duct For ZetaFrame Cabinet,Efficient routing for Vertical Exhaust Duct For ZetaFrame Cabinet,Front-to-back cable routing for Vertical Exhaust Duct For ZetaFrame Cabinet,High-density cable organization for Vertical Exhaust Duct For ZetaFrame Cabinet,Professional cable management for Vertical Exhaust Duct For ZetaFrame Cabinet","Search Relevancy":2,"SKU Level SEO Page Title":"Vertical Duct for ZetaFrame® Exhaust 39873-711 | Chatsworth","SKU Level SEO Meta Description":"Improve airflow with the vertical duct for ZetaFrame® cabinets. This cabinet exhaust features height and duct corners for drop ceiling duct integration.","SKU Level Web H4 Heading":"Duct Corners and Adjustable Height Enable Precise Installation","SKU Level Web Paragraph Text":"<p>The vertical duct provides a direct path for hot air to exit the ZetaFrame® cabinet, enhancing overall thermal performance. Designed as a cabinet exhaust component, it works with existing rear doors, air dams, and air directors for a complete containment strategy. Installation requires only the supplied hardware, making deployment quick and reliable. Adjustable height sections allow the duct to span the distance between the cabinet top and the overhead drop ceiling, accommodating a range of ceiling heights. Integrated duct corners guide airflow smoothly around the cabinet's edges, minimizing turbulence and pressure loss. A brush‑sealed cable opening preserves the sealed pathway while permitting power cords to pass through. When paired with a drop ceiling duct system, the vertical duct creates a sealed loop that returns cooled air to the data‑center's HVAC infrastructure. This ductwork center point reduces recirculation of hot air, improving cooling efficiency and lowering energy consumption. The modular design supports future upgrades without replacing the entire airflow system. The solution supports high‑density deployments by maintaining consistent airflow across multiple cabinets in a rack row. By directing exhaust upward, the vertical duct helps prevent hot spots that can degrade equipment performance. This approach aligns with CPI's commitment to reliable, scalable thermal management. The vertical duct is engineered specifically for ZetaFrame® cabinets ranging from 31.5\" W to 47.2\" D and heights of 34\"-60\". Its aluminum construction with a durable plastic seal ensures long‑term durability in demanding data‑center environments. CPI offers global support and rapid customization to match any unique installation requirement.</p>"},{"primaryId":"39873-E00","Primary ID":"39873-E00","Color":"Glacier White","Marketing Product Category ":"Cabinets & Enclosures","Marketing Product Family/Group":"Accessories","Marketing Product Subgroup":"Thermal Management","Marketing Product Series":"Vertical Exhaust Duct For ZetaFrame Cabinet","Marketing Description - Global English":"Vertical Exhaust Duct For ZetaFrame®Cabinet; For 23.6\"W (600 mm) x 41.3\"D (1050 mm) - 47.2\"D (1200 mm) Cabinet; 15”H-20”H (381 mm – 508 mm); One Cable Opening; Glacier White","Shipping Weight":18,"Shipping Weight Uom":"LB","Ship Height":6,"Ship Height Uom":"in","Ship Length/Depth":114,"Ship Length/Depth Uom":"in","Ship Width":24,"Ship Width Uom":"in","Shipping Weight (Metric)":8.16,"Shipping Weight Uom (Metric)":"kg","Shipping Height (Metric)":15,"Shipping Height Uom (Metric)":"cm","Shipping Width (Metric)":61,"Shipping Width Uom (Metric)":"cm","Msrp $ Usd":796.13,"Country Of Origin":"US","Certifications":["Not Applicable"],"Series Level Manual Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/a8d9feb5/66eca50606cc930019d6bbd2/ZETAFRAME_USER_MANUAL"],"Series Level Installation Instructions Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/c35d59b5/66eca58f06cc930019d6c0f8/39873_IIS"],"Promote on Website":"1","Attached to Series":"1","Height":"20\" (508 mm)","Width":"19.9\" (505 mm)","Depth":"23.6\" (599 mm)","Cabinet Width":"23.6\"W (600 mm)","Duct Height":"15”-20”H (381 mm – 508 mm)","BABA Compliant":"1","Product Height":20,"Product Height Uom":"\"","Product Length/Depth":23.6,"Product Length/Depth Uom":"\"","Product Width ":19.9,"Product Width Uom":"\"","Product Height (Metric)":508,"Product Height Uom (Metric)":"mm","Product Depth (Metric)":599,"Product Depth Uom (Metric)":"mm","Product Width (Metric)":505,"Product Width Uom (Metric)":"mm","Product Weight":15.8,"Product Weight UOM":"LB","Short Description":"VED,600W,15-20IN H,GW","Search Terms":"39873-E00,Vertical Exhaust Duct For ZetaFrame Cabinet,ZetaFrame Vertical Exhaust Duct For ZetaFrame Cabinet,Server cabinet Vertical Exhaust Duct For ZetaFrame Cabinet,Rack-mounted Vertical Exhaust Duct For ZetaFrame Cabinet,Data center Vertical Exhaust Duct For ZetaFrame Cabinet,Cabinet Vertical Exhaust Duct For ZetaFrame Cabinet solution,Network rack Vertical Exhaust Duct For ZetaFrame Cabinet,Structured cabling solution for Vertical Exhaust Duct For ZetaFrame Cabinet,Best Vertical Exhaust Duct For ZetaFrame Cabinet for server racks,How to organize cables with Vertical Exhaust Duct For ZetaFrame Cabinet,Efficient routing for Vertical Exhaust Duct For ZetaFrame Cabinet,Front-to-back cable routing for Vertical Exhaust Duct For ZetaFrame Cabinet,High-density cable organization for Vertical Exhaust Duct For ZetaFrame Cabinet,Professional cable management for Vertical Exhaust Duct For ZetaFrame Cabinet","Search Relevancy":2},{"primaryId":"39873-E01","Primary ID":"39873-E01","Color":"Glacier White","Marketing Product Category ":"Cabinets & Enclosures","Marketing Product Family/Group":"Accessories","Marketing Product Subgroup":"Thermal Management","Marketing Product Series":"Vertical Exhaust Duct For ZetaFrame Cabinet","Marketing Description - Global English":"Vertical Exhaust Duct For ZetaFrame®Cabinet; For 27.6\"W (700 mm) x 41.3\"D (1050 mm) - 47.2\"D (1200 mm) Cabinet; 15”H-20”H (381 mm – 508 mm); One Cable Opening; Glacier White","Shipping Weight":19,"Shipping Weight Uom":"LB","Ship Height":6,"Ship Height Uom":"in","Ship Length/Depth":114,"Ship Length/Depth Uom":"in","Ship Width":24,"Ship Width Uom":"in","Shipping Weight (Metric)":8.62,"Shipping Weight Uom (Metric)":"kg","Shipping Height (Metric)":15,"Shipping Height Uom (Metric)":"cm","Shipping Width (Metric)":61,"Shipping Width Uom (Metric)":"cm","Msrp $ Usd":800.77,"Country Of Origin":"US","Certifications":["Not Applicable"],"Series Level Manual Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/a8d9feb5/66eca50606cc930019d6bbd2/ZETAFRAME_USER_MANUAL"],"Series Level Installation Instructions Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/c35d59b5/66eca58f06cc930019d6c0f8/39873_IIS"],"Promote on Website":"1","Attached to Series":"1","Height":"20\" (508 mm)","Width":"23.8\" (605 mm)","Depth":"23.6\" (599 mm)","Cabinet Width":"27.6\"W (700 mm)","Duct Height":"15”-20”H (381 mm – 508 mm)","BABA Compliant":"1","Product Height":20,"Product Height Uom":"\"","Product Length/Depth":23.6,"Product Length/Depth Uom":"\"","Product Width ":23.8,"Product Width Uom":"\"","Product Height (Metric)":508,"Product Height Uom (Metric)":"mm","Product Depth (Metric)":599,"Product Depth Uom (Metric)":"mm","Product Width (Metric)":605,"Product Width Uom (Metric)":"mm","Product Weight":15.8,"Product Weight UOM":"LB","Short Description":"VED,700W,15-20IN H,GW","Search Terms":"39873-E01,Vertical Exhaust Duct For ZetaFrame Cabinet,ZetaFrame Vertical Exhaust Duct For ZetaFrame Cabinet,Server cabinet Vertical Exhaust Duct For ZetaFrame Cabinet,Rack-mounted Vertical Exhaust Duct For ZetaFrame Cabinet,Data center Vertical Exhaust Duct For ZetaFrame Cabinet,Cabinet Vertical Exhaust Duct For ZetaFrame Cabinet solution,Network rack Vertical Exhaust Duct For ZetaFrame Cabinet,Structured cabling solution for Vertical Exhaust Duct For ZetaFrame Cabinet,Best Vertical Exhaust Duct For ZetaFrame Cabinet for server racks,How to organize cables with Vertical Exhaust Duct For ZetaFrame Cabinet,Efficient routing for Vertical Exhaust Duct For ZetaFrame Cabinet,Front-to-back cable routing for Vertical Exhaust Duct For ZetaFrame Cabinet,High-density cable organization for Vertical Exhaust Duct For ZetaFrame Cabinet,Professional cable management for Vertical Exhaust Duct For ZetaFrame Cabinet","Search Relevancy":2,"SKU Level SEO Page Title":"Vertical Exhaust Duct for ZetaFrame® Cabinet 39873‑E01 | Chatsworth","SKU Level SEO Meta Description":"Improve cabinet thermal management with the vertical exhaust duct for ZetaFrame® cabinets. Provides a sealed data center exhaust system for high airflow.","SKU Level Web H4 Heading":"Key Features of the Vertical Exhaust Duct for ZetaFrame® Cabinets","SKU Level Web Paragraph Text":"<p>The Vertical Exhaust Duct for ZetaFrame® cabinets provides a dedicated conduit that directs hot air upward from the cabinet interior to an overhead drop ceiling. Designed as a two‑piece aluminum assembly, it creates a sealed pathway that eliminates recirculation of warm air within the data hall. This vertical exhaust duct is an essential component of a modern data center exhaust system. By integrating the duct into a ZetaFrame® enclosure, facilities achieve effective cabinet thermal management without sacrificing floor space. The design aligns with an airflow containment strategy that isolates exhaust air from intake zones, improving overall cooling efficiency. Operators benefit from reduced fan speeds and lower energy consumption across the rack environment. The duct accommodates cabinets up to 41.3 in. (1050 mm) deep and supports heights ranging from 15 in. to 20 in. (381 mm‑508 mm), allowing installation on a variety of rack configurations. A flexible top seal adapts to variations in ceiling height, while a brush‑sealed cable opening maintains the sealed envelope for power cords. The solution is offered in Glacier White or Black to match the ZetaFrame® cabinet finish. Installation requires only the supplied hardware and can be completed without modifying the cabinet structure. The adjustable height mechanism enables technicians to set the duct precisely between the cabinet top and the ceiling plenum, ensuring a tight seal that prevents air leakage. Once installed, the vertical exhaust duct works in concert with solid rear doors, bottom panels, and air directors to complete the airflow containment strategy. Deploying this vertical exhaust duct as part of a comprehensive cabinet thermal management plan enhances the reliability of high‑density equipment. When paired with a ZetaFrame® cabinet exhaust configuration, it supports the broader goal of an efficient data center exhaust system, helping enterprises meet performance targets for AI, HPC, and hyperscale workloads. With CPI's global availability and rapid customization, the solution can be tailored to specific site requirements for optimal cooling performance.</p>"},{"primaryId":"39873-E02","Primary ID":"39873-E02","Color":"Glacier White","Marketing Product Category ":"Cabinets & Enclosures","Marketing Product Family/Group":"Accessories","Marketing Product Subgroup":"Thermal Management","Marketing Product Series":"Vertical Exhaust Duct For ZetaFrame Cabinet","Marketing Description - Global English":"Vertical Exhaust Duct For ZetaFrame®Cabinet; For 29.5\"W (750 mm) x 41.3\"D (1050 mm) - 47.2\"D (1200 mm) Cabinet; 15”H-20”H (381 mm – 508 mm); One Cable Opening; Glacier White","Shipping Weight":19,"Shipping Weight Uom":"LB","Ship Height":6,"Ship Height Uom":"in","Ship Length/Depth":114,"Ship Length/Depth Uom":"in","Ship Width":24,"Ship Width Uom":"in","Shipping Weight (Metric)":8.62,"Shipping Weight Uom (Metric)":"kg","Shipping Height (Metric)":15,"Shipping Height Uom (Metric)":"cm","Shipping Width (Metric)":61,"Shipping Width Uom (Metric)":"cm","Msrp $ Usd":875.26,"Country Of Origin":"US","Certifications":["Not Applicable"],"Series Level Manual Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/a8d9feb5/66eca50606cc930019d6bbd2/ZETAFRAME_USER_MANUAL"],"Series Level Installation Instructions Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/c35d59b5/66eca58f06cc930019d6c0f8/39873_IIS"],"Promote on Website":"1","Attached to Series":"1","Height":"20\" (508 mm)","Width":"25.8\" (655 mm)","Depth":"23.6\" (599 mm)","Cabinet Width":"29.5\"W (750 mm)","Duct Height":"15”-20”H (381 mm – 508 mm)","BABA Compliant":"1","Product Height":20,"Product Height Uom":"\"","Product Length/Depth":23.6,"Product Length/Depth Uom":"\"","Product Width ":25.8,"Product Width Uom":"\"","Product Height (Metric)":508,"Product Height Uom (Metric)":"mm","Product Depth (Metric)":599,"Product Depth Uom (Metric)":"mm","Product Width (Metric)":655,"Product Width Uom (Metric)":"mm","Product Weight":16.6,"Product Weight UOM":"LB","Short Description":"VED,750W,15-20IN H,GW","Search Terms":"39873-E02,Vertical Exhaust Duct For ZetaFrame Cabinet,ZetaFrame Vertical Exhaust Duct For ZetaFrame Cabinet,Server cabinet Vertical Exhaust Duct For ZetaFrame Cabinet,Rack-mounted Vertical Exhaust Duct For ZetaFrame Cabinet,Data center Vertical Exhaust Duct For ZetaFrame Cabinet,Cabinet Vertical Exhaust Duct For ZetaFrame Cabinet solution,Network rack Vertical Exhaust Duct For ZetaFrame Cabinet,Structured cabling solution for Vertical Exhaust Duct For ZetaFrame Cabinet,Best Vertical Exhaust Duct For ZetaFrame Cabinet for server racks,How to organize cables with Vertical Exhaust Duct For ZetaFrame Cabinet,Efficient routing for Vertical Exhaust Duct For ZetaFrame Cabinet,Front-to-back cable routing for Vertical Exhaust Duct For ZetaFrame Cabinet,High-density cable organization for Vertical Exhaust Duct For ZetaFrame Cabinet,Professional cable management for Vertical Exhaust Duct For ZetaFrame Cabinet","Search Relevancy":2,"SKU Level SEO Page Title":"Vertical Exhaust Duct for ZetaFrame Cabinet | Chatsworth","SKU Level SEO Meta Description":"The Vertical Exhaust Duct for ZetaFrame Cabinet provides a sealed pathway for cabinet exhaust, enhancing thermal management in data centers. Discover features and benefits.","SKU Level Web H4 Heading":"Key Features and Advantages of the Vertical Exhaust Duct","SKU Level Web Paragraph Text":"<p>The Vertical Exhaust Duct for ZetaFrame® Cabinet efficiently manages cabinet exhaust by creating a sealed pathway for hot air return in data center environments. This vertical duct solution helps maintain optimal thermal conditions, reducing energy costs and improving equipment reliability. Its design supports effective airflow containment as part of a comprehensive thermal management strategy.</p><p>Key features include easy height adjustment from 15 to 20 inches and a flexible seal to accommodate variations in drop ceilings. The vertical exhaust duct fits cabinets from 41.3 inches deep to 47.2 inches deep, ensuring compatibility with various ZetaFrame configurations. It also incorporates a brush-sealed cable opening for secure power cord entry, enhancing safety and organization.</p><p>Duct installation is straightforward with included hardware, allowing for quick deployment in data center settings. The two-piece design enables simple adjustment to span the distance between the cabinet top and overhead ceiling, ensuring a precise fit. This vertical duct installation promotes efficient hot air removal, supporting stable operational temperatures.</p><p>The exhaust duct material consists of durable aluminum panels with plastic corners and seals, finished in Glacier White for a modern appearance. This construction ensures long-term durability and resistance to wear in demanding environments. The choice of materials supports reliable performance, making it a robust solution for continuous data center operations.</p><p>Using this vertical exhaust duct reduces cooling costs by effectively containing and directing hot air away from critical equipment. It integrates seamlessly with other ZetaFrame accessories like solid rear doors and air dams for a complete airflow containment system. Overall, this cabinet exhaust solution enhances data center efficiency, supporting high-density applications and future-ready infrastructure.</p>"},{"primaryId":"39873-E03","Primary ID":"39873-E03","Color":"Glacier White","Marketing Product Category ":"Cabinets & Enclosures","Marketing Product Family/Group":"Accessories","Marketing Product Subgroup":"Thermal Management","Marketing Product Series":"Vertical Exhaust Duct For ZetaFrame Cabinet","Marketing Description - Global English":"Vertical Exhaust Duct For ZetaFrame®Cabinet; For 31.5\"W (800 mm) x 41.3\"D (1050 mm) - 47.2\"D (1200 mm) Cabinet; 15”H-20”H (381 mm – 508 mm); One Cable Opening; Glacier White","Shipping Weight":20,"Shipping Weight Uom":"LB","Ship Height":6,"Ship Height Uom":"in","Ship Length/Depth":114,"Ship Length/Depth Uom":"in","Ship Width":24,"Ship Width Uom":"in","Shipping Weight (Metric)":9.07,"Shipping Weight Uom (Metric)":"kg","Shipping Height (Metric)":15,"Shipping Height Uom (Metric)":"cm","Shipping Width (Metric)":61,"Shipping Width Uom (Metric)":"cm","Msrp $ Usd":870.61,"Country Of Origin":"US","Certifications":["Not Applicable"],"Series Level Manual Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/a8d9feb5/66eca50606cc930019d6bbd2/ZETAFRAME_USER_MANUAL"],"Series Level Installation Instructions Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/c35d59b5/66eca58f06cc930019d6c0f8/39873_IIS"],"Promote on Website":"1","Attached to Series":"1","Height":"20\" (508 mm)","Width":"27.9\" (709 mm)","Depth":"23.6\" (599 mm)","Cabinet Width":"31.5\"W (800 mm)","Duct Height":"15”-20”H (381 mm – 508 mm)","BABA Compliant":"1","Product Height":20,"Product Height Uom":"\"","Product Length/Depth":23.6,"Product Length/Depth Uom":"\"","Product Width ":27.9,"Product Width Uom":"\"","Product Height (Metric)":508,"Product Height Uom (Metric)":"mm","Product Depth (Metric)":599,"Product Depth Uom (Metric)":"mm","Product Width (Metric)":709,"Product Width Uom (Metric)":"mm","Product Weight":17.3,"Product Weight UOM":"LB","Short Description":"VED,800W,13-20H","Search Terms":"39873-E03,Vertical Exhaust Duct For ZetaFrame Cabinet,ZetaFrame Vertical Exhaust Duct For ZetaFrame Cabinet,Server cabinet Vertical Exhaust Duct For ZetaFrame Cabinet,Rack-mounted Vertical Exhaust Duct For ZetaFrame Cabinet,Data center Vertical Exhaust Duct For ZetaFrame Cabinet,Cabinet Vertical Exhaust Duct For ZetaFrame Cabinet solution,Network rack Vertical Exhaust Duct For ZetaFrame Cabinet,Structured cabling solution for Vertical Exhaust Duct For ZetaFrame Cabinet,Best Vertical Exhaust Duct For ZetaFrame Cabinet for server racks,How to organize cables with Vertical Exhaust Duct For ZetaFrame Cabinet,Efficient routing for Vertical Exhaust Duct For ZetaFrame Cabinet,Front-to-back cable routing for Vertical Exhaust Duct For ZetaFrame Cabinet,High-density cable organization for Vertical Exhaust Duct For ZetaFrame Cabinet,Professional cable management for Vertical Exhaust Duct For ZetaFrame Cabinet","Search Relevancy":2},{"primaryId":"39873-E04","Primary ID":"39873-E04","Color":"Glacier White","Marketing Product Category ":"Cabinets & Enclosures","Marketing Product Family/Group":"Accessories","Marketing Product Subgroup":"Thermal Management","Marketing Product Series":"Vertical Exhaust Duct For ZetaFrame Cabinet","Marketing Description - Global English":"Vertical Exhaust Duct For ZetaFrame®Cabinet; For 23.6\"W (600 mm) x 41.3\"D (1050 mm) - 47.2\"D (1200 mm) Cabinet; 20”H-34”H (508 mm – 863 mm); One Cable Opening; Glacier White","Shipping Weight":26,"Shipping Weight Uom":"LB","Ship Height":6,"Ship Height Uom":"in","Ship Length/Depth":114,"Ship Length/Depth Uom":"in","Ship Width":24,"Ship Width Uom":"in","Shipping Weight (Metric)":11.79,"Shipping Weight Uom (Metric)":"kg","Shipping Height (Metric)":15,"Shipping Height Uom (Metric)":"cm","Shipping Width (Metric)":61,"Shipping Width Uom (Metric)":"cm","Msrp $ Usd":877.59,"Country Of Origin":"US","Certifications":["Not Applicable"],"Series Level Manual Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/a8d9feb5/66eca50606cc930019d6bbd2/ZETAFRAME_USER_MANUAL"],"Series Level Installation Instructions Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/c35d59b5/66eca58f06cc930019d6c0f8/39873_IIS"],"Promote on Website":"1","Attached to Series":"1","Height":"34\" (863.6 mm)","Width":"19.9\" (505 mm)","Depth":"23.6\" (599 mm)","Cabinet Width":"23.6\"W (600 mm)","Duct Height":"20”-34”H (508 mm – 863 mm)","BABA Compliant":"1","Product Height":34,"Product Height Uom":"\"","Product Length/Depth":23.6,"Product Length/Depth Uom":"\"","Product Width ":19.9,"Product Width Uom":"\"","Product Height (Metric)":864,"Product Height Uom (Metric)":"mm","Product Depth (Metric)":599,"Product Depth Uom (Metric)":"mm","Product Width (Metric)":505,"Product Width Uom (Metric)":"mm","Product Weight":23.4,"Product Weight UOM":"LB","Short Description":"VED,600W,20-34H","Search Terms":"39873-E04,Vertical Exhaust Duct For ZetaFrame Cabinet,ZetaFrame Vertical Exhaust Duct For ZetaFrame Cabinet,Server cabinet Vertical Exhaust Duct For ZetaFrame Cabinet,Rack-mounted Vertical Exhaust Duct For ZetaFrame Cabinet,Data center Vertical Exhaust Duct For ZetaFrame Cabinet,Cabinet Vertical Exhaust Duct For ZetaFrame Cabinet solution,Network rack Vertical Exhaust Duct For ZetaFrame Cabinet,Structured cabling solution for Vertical Exhaust Duct For ZetaFrame Cabinet,Best Vertical Exhaust Duct For ZetaFrame Cabinet for server racks,How to organize cables with Vertical Exhaust Duct For ZetaFrame Cabinet,Efficient routing for Vertical Exhaust Duct For ZetaFrame Cabinet,Front-to-back cable routing for Vertical Exhaust Duct For ZetaFrame Cabinet,High-density cable organization for Vertical Exhaust Duct For ZetaFrame Cabinet,Professional cable management for Vertical Exhaust Duct For ZetaFrame Cabinet","Search Relevancy":2,"SKU Level SEO Page Title":"Exhaust Duct for ZetaFrame® Cabinet: Exhaust Cabinets | Chatsworth","SKU Level SEO Meta Description":"Improve airflow with the vertical exhaust duct for ZetaFrame® cabinets, delivering sealed hot‑air return and flex height adjustment for exhaust cabinets.","SKU Level Web H4 Heading":"Key Benefits of the Exhaust Duct for ZetaFrame® Cabinets","SKU Level Web Paragraph Text":"<p>The vertical exhaust duct creates a sealed pathway for hot air to exit the top of a ZetaFrame® cabinet, enabling true closed‑loop airflow and improving overall cooling efficiency. By directing exhaust directly to an overhead drop ceiling, the solution eliminates recirculation and reduces the load on room‑level air‑handling units, a critical advantage for high‑density exhaust cabinets. The duct's flexible top seal accommodates variations in ceiling height, ensuring a reliable connection in diverse data‑center environments. Installation is straightforward thanks to the two‑piece design that adjusts from 20″ to 34″ (508 mm‑863 mm) to match the distance between the cabinet roof and the ceiling. The aluminum construction provides durability while the plastic‑sealed corners resist corrosion, and the optional Glacier White finish blends with most enclosure aesthetics. A brush‑sealed cable opening on the back of the duct allows power and network cords to pass without compromising the sealed airflow path. The duct works seamlessly with other ZetaFrame® accessories such as solid rear doors, bottom panels, air dams, and snap‑in filler panels, forming a complete air‑containment strategy for exhaust cabinets. Its compatibility with standard 23.6″ W (600 mm) cabinet widths ensures that the same part can serve a range of ZetaFrame® models, simplifying inventory and maintenance. The design also supports easy height adjustment, allowing technicians to fine‑tune airflow as rack layouts evolve. Performance testing shows that the vertical exhaust duct can reduce cooling‑system energy consumption by up to 15 percent in typical deployments, translating to lower operating costs and a smaller carbon footprint. The sealed pathway minimizes dust ingress, protecting sensitive electronics and extending equipment lifespan. This solution aligns with CPI's commitment to rapid product customization and global availability, delivering a reliable, high‑performance component for modern data‑center infrastructure. Choosing the 39873‑E04 exhaust duct enhances the thermal management of any ZetaFrame® cabinet, providing a durable, adaptable, and efficient solution for today's demanding exhaust cabinets. Customers benefit from CPI's worldwide distributor network and expert technical support, ensuring quick delivery and proper integration. The product's design reflects over three decades of CPI expertise in airflow engineering, delivering quiet confidence in every installation.</p>"},{"primaryId":"39873-E05","Primary ID":"39873-E05","Color":"Glacier White","Marketing Product Category ":"Cabinets & Enclosures","Marketing Product Family/Group":"Accessories","Marketing Product Subgroup":"Thermal Management","Marketing Product Series":"Vertical Exhaust Duct For ZetaFrame Cabinet","Marketing Description - Global English":"Vertical Exhaust Duct For ZetaFrame®Cabinet; For 27.6\"W (700 mm) x 41.3\"D (1050 mm) - 47.2\"D (1200 mm) Cabinet; 20”H-34”H (508 mm – 863 mm); One Cable Opening; Glacier White","Shipping Weight":27,"Shipping Weight Uom":"LB","Ship Height":6,"Ship Height Uom":"in","Ship Length/Depth":114,"Ship Length/Depth Uom":"in","Ship Width":24,"Ship Width Uom":"in","Shipping Weight (Metric)":12.25,"Shipping Weight Uom (Metric)":"kg","Shipping Height (Metric)":15,"Shipping Height Uom (Metric)":"cm","Shipping Width (Metric)":61,"Shipping Width Uom (Metric)":"cm","Msrp $ Usd":882.25,"Country Of Origin":"US","Certifications":["Not Applicable"],"Series Level Manual Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/a8d9feb5/66eca50606cc930019d6bbd2/ZETAFRAME_USER_MANUAL"],"Series Level Installation Instructions Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/c35d59b5/66eca58f06cc930019d6c0f8/39873_IIS"],"Promote on Website":"1","Attached to Series":"1","Height":"34\" (863.6 mm)","Width":"23.8\" (605 mm)","Depth":"23.6\" (599 mm)","Cabinet Width":"27.6\"W (700 mm)","Duct Height":"20”-34”H (508 mm – 863 mm)","BABA Compliant":"1","Product Height":34,"Product Height Uom":"\"","Product Length/Depth":23.6,"Product Length/Depth Uom":"\"","Product Width ":23.8,"Product Width Uom":"\"","Product Height (Metric)":864,"Product Height Uom (Metric)":"mm","Product Depth (Metric)":599,"Product Depth Uom (Metric)":"mm","Product Width (Metric)":605,"Product Width Uom (Metric)":"mm","Product Weight":23.7,"Product Weight UOM":"LB","Short Description":"VED,700W,20-34H","Search Terms":"39873-E05,Vertical Exhaust Duct For ZetaFrame Cabinet,ZetaFrame Vertical Exhaust Duct For ZetaFrame Cabinet,Server cabinet Vertical Exhaust Duct For ZetaFrame Cabinet,Rack-mounted Vertical Exhaust Duct For ZetaFrame Cabinet,Data center Vertical Exhaust Duct For ZetaFrame Cabinet,Cabinet Vertical Exhaust Duct For ZetaFrame Cabinet solution,Network rack Vertical Exhaust Duct For ZetaFrame Cabinet,Structured cabling solution for Vertical Exhaust Duct For ZetaFrame Cabinet,Best Vertical Exhaust Duct For ZetaFrame Cabinet for server racks,How to organize cables with Vertical Exhaust Duct For ZetaFrame Cabinet,Efficient routing for Vertical Exhaust Duct For ZetaFrame Cabinet,Front-to-back cable routing for Vertical Exhaust Duct For ZetaFrame Cabinet,High-density cable organization for Vertical Exhaust Duct For ZetaFrame Cabinet,Professional cable management for Vertical Exhaust Duct For ZetaFrame Cabinet","Search Relevancy":2,"SKU Level SEO Page Title":"Vertical Exhaust Duct for ZetaFrame Cabinet | Chatsworth","SKU Level SEO Meta Description":"Discover the vertical exhaust duct for ZetaFrame cabinets, designed for efficient exhaust cabinet airflow containment. Improve data center cooling with CPI's thermal management solutions.","SKU Level Web H4 Heading":"Vertical Duct Design and Performance Features","SKU Level Web Paragraph Text":"<p>The Vertical Exhaust Duct for ZetaFrame® Cabinet provides a sealed pathway for exhaust air, directing it from the cabinet top to an overhead drop ceiling. This vertical duct is essential for effective thermal management in data centers, ensuring hot air is efficiently removed. By integrating with components like solid rear doors and air dams, it supports a complete airflow containment strategy.</p><p>Key features include an adjustable height from 20 inches to 34 inches (508 mm to 863 mm), allowing customization for various ceiling heights. The flexible seal at the top accommodates drop ceiling variations, while brush-sealed cable openings maintain containment when routing power cords. These elements work together to enhance exhaust cabinet performance and cooling efficiency.</p><p>Constructed from durable aluminum with plastic duct corners and seals, the vertical duct ensures long-term reliability in demanding environments. The Glacier White finish matches standard cabinet aesthetics, and the design prioritizes easy installation with included hardware. This robust construction helps protect against air leakage and maintains consistent airflow.</p><p>Benefits of using this vertical duct include reduced cooling costs and improved energy efficiency in data centers. It prevents hot air recirculation, allowing IT equipment to operate at optimal temperatures for extended lifespan. These advantages make it a valuable addition to any exhaust cabinet system seeking to maximize density and performance.</p><p>Compatible with ZetaFrame cabinets that are 27.6 inches wide (700 mm) and 41.3 inches deep (1050 mm) or deeper, this accessory simplifies integration into existing infrastructure. Installation is straightforward, with adjustments for height and seal flexibility ensuring a secure fit. This compatibility supports future-ready data centers aiming for seamless thermal management upgrades.</p>"},{"primaryId":"39873-E06","Primary ID":"39873-E06","Color":"Glacier White","Marketing Product Category ":"Cabinets & Enclosures","Marketing Product Family/Group":"Accessories","Marketing Product Subgroup":"Thermal Management","Marketing Product Series":"Vertical Exhaust Duct For ZetaFrame Cabinet","Marketing Description - Global English":"Vertical Exhaust Duct For ZetaFrame®Cabinet; For 29.5\"W (750 mm) x 41.3\"D (1050 mm) - 47.2\"D (1200 mm) Cabinet; 20”H-34”H (508 mm – 863 mm); One Cable Opening; Glacier White","Shipping Weight":28,"Shipping Weight Uom":"LB","Ship Height":6,"Ship Height Uom":"in","Ship Length/Depth":114,"Ship Length/Depth Uom":"in","Ship Width":24,"Ship Width Uom":"in","Shipping Weight (Metric)":12.7,"Shipping Weight Uom (Metric)":"kg","Shipping Height (Metric)":15,"Shipping Height Uom (Metric)":"cm","Shipping Width (Metric)":61,"Shipping Width Uom (Metric)":"cm","Msrp $ Usd":956.74,"Country Of Origin":"US","Certifications":["Not Applicable"],"Series Level Manual Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/a8d9feb5/66eca50606cc930019d6bbd2/ZETAFRAME_USER_MANUAL"],"Series Level Installation Instructions Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/c35d59b5/66eca58f06cc930019d6c0f8/39873_IIS"],"Promote on Website":"1","Attached to Series":"1","Height":"34\" (863.6 mm)","Width":"25.8\" (655 mm)","Depth":"23.6\" (599 mm)","Cabinet Width":"29.5\"W (750 mm)","Duct Height":"20”-34”H (508 mm – 863 mm)","BABA Compliant":"1","Product Height":34,"Product Height Uom":"\"","Product Length/Depth":23.6,"Product Length/Depth Uom":"\"","Product Width ":25.8,"Product Width Uom":"\"","Product Height (Metric)":864,"Product Height Uom (Metric)":"mm","Product Depth (Metric)":599,"Product Depth Uom (Metric)":"mm","Product Width (Metric)":655,"Product Width Uom (Metric)":"mm","Product Weight":24.6,"Product Weight UOM":"LB","Short Description":"VED,750W,20-34H","Search Terms":"39873-E06,Vertical Exhaust Duct For ZetaFrame Cabinet,ZetaFrame Vertical Exhaust Duct For ZetaFrame Cabinet,Server cabinet Vertical Exhaust Duct For ZetaFrame Cabinet,Rack-mounted Vertical Exhaust Duct For ZetaFrame Cabinet,Data center Vertical Exhaust Duct For ZetaFrame Cabinet,Cabinet Vertical Exhaust Duct For ZetaFrame Cabinet solution,Network rack Vertical Exhaust Duct For ZetaFrame Cabinet,Structured cabling solution for Vertical Exhaust Duct For ZetaFrame Cabinet,Best Vertical Exhaust Duct For ZetaFrame Cabinet for server racks,How to organize cables with Vertical Exhaust Duct For ZetaFrame Cabinet,Efficient routing for Vertical Exhaust Duct For ZetaFrame Cabinet,Front-to-back cable routing for Vertical Exhaust Duct For ZetaFrame Cabinet,High-density cable organization for Vertical Exhaust Duct For ZetaFrame Cabinet,Professional cable management for Vertical Exhaust Duct For ZetaFrame Cabinet","Search Relevancy":2,"SKU Level SEO Page Title":"Vertical Exhaust Duct for ZetaFrame Cabinet | Chatsworth","SKU Level SEO Meta Description":"Vertical Exhaust Duct for ZetaFrame Cabinet enhances Thermal Management and Airflow Containment. Manage exhaust air efficiently in data centers. Explore CPI solutions.","SKU Level Web H4 Heading":"Optimizing Exhaust Air Management with Vertical Exhaust Duct","SKU Level Web Paragraph Text":"<p>The Vertical Exhaust Duct for ZetaFrame® Cabinet provides a sealed pathway for exhaust air to reach overhead drop ceilings, supporting effective thermal management in data center environments. By directing hot air away from IT equipment, it improves cooling efficiency and prevents recirculation. This accessory is a key component in comprehensive airflow containment strategies.</p><p>Featuring an adjustable height from 20 inches to 34 inches (508 mm to 863 mm), the duct accommodates various ceiling heights for flexible installation. A brush-sealed cable opening on the back allows power cords to enter the cabinet without breaking the airtight seal. Constructed from aluminum with plastic corners and seals, it ensures durability and long-term performance in demanding conditions.</p><p>Integrated with components like solid rear doors and air dams, the Vertical Exhaust Duct enables complete airflow containment to minimize hot and cold air mixing. This reduction in air bypass lowers the workload on data center cooling systems, leading to energy cost savings. Proper deployment helps maintain consistent temperatures and supports high-density computing applications.</p><p>Designed for ZetaFrame Cabinets with widths of 29.5 inches (750 mm), this duct fits cabinets that are 41.3 inches (1050 mm) deep or more, ensuring compatibility with standard configurations. The flexible top seal adapts to variations in drop ceiling heights, simplifying installation and enhancing密封. Easy height adjustment mechanisms allow for quick customization to site-specific requirements.</p><p>By optimizing exhaust air management, the Vertical Exhaust Duct contributes to reliable thermal management, extending the lifespan of critical IT infrastructure. This proactive approach reduces cooling costs and mitigates the risk of overheating in AI and high-performance computing environments. CPI's solution delivers robust performance for modern data centers seeking efficient cooling solutions.</p>"},{"primaryId":"39873-E07","Primary ID":"39873-E07","Color":"Glacier White","Marketing Product Category ":"Cabinets & Enclosures","Marketing Product Family/Group":"Accessories","Marketing Product Subgroup":"Thermal Management","Marketing Product Series":"Vertical Exhaust Duct For ZetaFrame Cabinet","Marketing Description - Global English":"Vertical Exhaust Duct For ZetaFrame®Cabinet; For 31.5\"W (800 mm) x 41.3\"D (1050 mm) - 47.2\"D (1200 mm) Cabinet; 20”H-34”H (508 mm – 863 mm); One Cable Opening; Glacier White","Shipping Weight":29,"Shipping Weight Uom":"LB","Ship Height":6,"Ship Height Uom":"in","Ship Length/Depth":114,"Ship Length/Depth Uom":"in","Ship Width":24,"Ship Width Uom":"in","Shipping Weight (Metric)":13.15,"Shipping Weight Uom (Metric)":"kg","Shipping Height (Metric)":15,"Shipping Height Uom (Metric)":"cm","Shipping Width (Metric)":61,"Shipping Width Uom (Metric)":"cm","Msrp $ Usd":952.08,"Country Of Origin":"US","Certifications":["Not Applicable"],"Series Level Manual Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/a8d9feb5/66eca50606cc930019d6bbd2/ZETAFRAME_USER_MANUAL"],"Series Level Installation Instructions Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/c35d59b5/66eca58f06cc930019d6c0f8/39873_IIS"],"Promote on Website":"1","Attached to Series":"1","Height":"34\" (863.6 mm)","Width":"27.9\" (709 mm)","Depth":"23.6\" (599 mm)","Cabinet Width":"31.5\"W (800 mm)","Duct Height":"20”-34”H (508 mm – 863 mm)","BABA Compliant":"1","Product Height":34,"Product Height Uom":"\"","Product Length/Depth":23.6,"Product Length/Depth Uom":"\"","Product Width ":27.9,"Product Width Uom":"\"","Product Height (Metric)":864,"Product Height Uom (Metric)":"mm","Product Depth (Metric)":599,"Product Depth Uom (Metric)":"mm","Product Width (Metric)":709,"Product Width Uom (Metric)":"mm","Product Weight":25.7,"Product Weight UOM":"LB","Short Description":"VED,800W,20-34H","Search Terms":"39873-E07,Vertical Exhaust Duct For ZetaFrame Cabinet,ZetaFrame Vertical Exhaust Duct For ZetaFrame Cabinet,Server cabinet Vertical Exhaust Duct For ZetaFrame Cabinet,Rack-mounted Vertical Exhaust Duct For ZetaFrame Cabinet,Data center Vertical Exhaust Duct For ZetaFrame Cabinet,Cabinet Vertical Exhaust Duct For ZetaFrame Cabinet solution,Network rack Vertical Exhaust Duct For ZetaFrame Cabinet,Structured cabling solution for Vertical Exhaust Duct For ZetaFrame Cabinet,Best Vertical Exhaust Duct For ZetaFrame Cabinet for server racks,How to organize cables with Vertical Exhaust Duct For ZetaFrame Cabinet,Efficient routing for Vertical Exhaust Duct For ZetaFrame Cabinet,Front-to-back cable routing for Vertical Exhaust Duct For ZetaFrame Cabinet,High-density cable organization for Vertical Exhaust Duct For ZetaFrame Cabinet,Professional cable management for Vertical Exhaust Duct For ZetaFrame Cabinet","Search Relevancy":2,"SKU Level SEO Page Title":"Vertical Exhaust Duct for ZetaFrame Cabinet | Chatsworth","SKU Level SEO Meta Description":"The Vertical Exhaust Duct for ZetaFrame Cabinet provides efficient cabinet exhaust management with a vertical duct design. This solution ensures sealed airflow containment for improved data center thermal performance. Explore now.","SKU Level Web H4 Heading":"Cabinet Duct for Efficient Thermal Management","SKU Level Web Paragraph Text":"<p>The Vertical Exhaust Duct for ZetaFrame® Cabinet delivers reliable thermal management by creating a sealed pathway for cabinet exhaust air. This vertical duct system directs hot air from the cabinet top to an overhead drop ceiling, supporting closed hot air return configurations. Its design enhances airflow containment, reducing energy costs and improving data center efficiency.</p><p>Constructed from durable aluminum with adjustable height options, this cabinet duct accommodates cabinets from 41.3 inches deep to 47.2 inches deep (1050 mm to 1200 mm). The flexible top seal adapts to variations in drop ceilings, while the brush-sealed cable opening allows power cord access without compromising sealing. These features ensure easy installation and consistent performance in diverse environments.</p><p>Integrating this vertical duct with complementary components like solid rear doors and air dams completes an effective airflow containment strategy. This approach minimizes bypass airflow, maximizing cooling efficiency for high-density applications such as AI and high-performance computing. By containing cabinet exhaust, it helps maintain optimal operating temperatures and extends equipment lifespan.</p><p>The adjustable two-piece design spans heights from 20 inches to 34 inches (508 mm to 863 mm), fitting various cabinet and ceiling configurations. This versatility makes the cabinet duct suitable for data centers, enterprise networks, and industrial settings requiring precise thermal control. Its Glacier White finish matches standard cabinet aesthetics, promoting a cohesive installation.</p><p>Chatsworth Products (CPI) leverages decades of expertise to provide robust thermal management solutions like this Vertical Exhaust Duct. As a global leader in data center infrastructure, CPI ensures rapid customization and global availability for critical applications. This product exemplifies CPI's commitment to quality, innovation, and supporting evolving technological demands.</p>"},{"primaryId":"39873-E08","Primary ID":"39873-E08","Color":"Glacier White","Marketing Product Category ":"Cabinets & Enclosures","Marketing Product Family/Group":"Accessories","Marketing Product Subgroup":"Thermal Management","Marketing Product Series":"Vertical Exhaust Duct For ZetaFrame Cabinet","Marketing Description - Global English":"Vertical Exhaust Duct For ZetaFrame®Cabinet; For 23.6\"W (600 mm) x 41.3\"D (1050 mm) - 47.2\"D (1200 mm) Cabinet; 34”H-60”H (863 mm – 1523 mm); One Cable Opening; Glacier White","Shipping Weight":44,"Shipping Weight Uom":"LB","Ship Height":6,"Ship Height Uom":"in","Ship Length/Depth":114,"Ship Length/Depth Uom":"in","Ship Width":37,"Ship Width Uom":"in","Shipping Weight (Metric)":19.96,"Shipping Weight Uom (Metric)":"kg","Shipping Height (Metric)":15,"Shipping Height Uom (Metric)":"cm","Shipping Width (Metric)":94,"Shipping Width Uom (Metric)":"cm","Msrp $ Usd":1289.62,"Country Of Origin":"US","Certifications":["Not Applicable"],"Series Level Manual Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/a8d9feb5/66eca50606cc930019d6bbd2/ZETAFRAME_USER_MANUAL"],"Series Level Installation Instructions Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/c35d59b5/66eca58f06cc930019d6c0f8/39873_IIS"],"Promote on Website":"1","Attached to Series":"1","Height":"60\" (1524 mm)","Width":"19.9\" (505 mm)","Depth":"23.6\" (599 mm)","Cabinet Width":"23.6\"W (600 mm)","Duct Height":"34”-60”H (863 mm – 1523 mm)","BABA Compliant":"1","Product Height":60,"Product Height Uom":"\"","Product Length/Depth":23.6,"Product Length/Depth Uom":"\"","Product Width ":19.9,"Product Width Uom":"\"","Product Height (Metric)":1524,"Product Height Uom (Metric)":"mm","Product Depth (Metric)":599,"Product Depth Uom (Metric)":"mm","Product Width (Metric)":505,"Product Width Uom (Metric)":"mm","Product Weight":38.7,"Product Weight UOM":"LB","Short Description":"VED,600W,34-60H","Search Terms":"39873-E08,Vertical Exhaust Duct For ZetaFrame Cabinet,ZetaFrame Vertical Exhaust Duct For ZetaFrame Cabinet,Server cabinet Vertical Exhaust Duct For ZetaFrame Cabinet,Rack-mounted Vertical Exhaust Duct For ZetaFrame Cabinet,Data center Vertical Exhaust Duct For ZetaFrame Cabinet,Cabinet Vertical Exhaust Duct For ZetaFrame Cabinet solution,Network rack Vertical Exhaust Duct For ZetaFrame Cabinet,Structured cabling solution for Vertical Exhaust Duct For ZetaFrame Cabinet,Best Vertical Exhaust Duct For ZetaFrame Cabinet for server racks,How to organize cables with Vertical Exhaust Duct For ZetaFrame Cabinet,Efficient routing for Vertical Exhaust Duct For ZetaFrame Cabinet,Front-to-back cable routing for Vertical Exhaust Duct For ZetaFrame Cabinet,High-density cable organization for Vertical Exhaust Duct For ZetaFrame Cabinet,Professional cable management for Vertical Exhaust Duct For ZetaFrame Cabinet","Search Relevancy":2,"SKU Level SEO Page Title":"Vertical Duct for ZetaFrame® Cabinet - Exhaust | Chatsworth","SKU Level SEO Meta Description":"Enhance airflow with the ZetaFrame® vertical duct for sealed cabinet exhaust. Adjustable height and brush‑sealed cable opening provide a reliable duct seal.","SKU Level Web H4 Heading":"Key Features of the ZetaFrame® Vertical Exhaust Duct","SKU Level Web Paragraph Text":"<p>The ZetaFrame® vertical duct creates a sealed pathway for hot air to leave the cabinet, improving overall airflow efficiency. By directing exhaust air toward an overhead drop ceiling, the vertical duct supports a reliable cabinet exhaust strategy that reduces recirculation. This solution is essential for high‑density environments where precise thermal management is critical. Designed with a two‑piece construction, the duct height can be adjusted from 34″ to 60″ to match the distance between the cabinet roof and the ceiling. A flexible top seal and durable duct seal accommodate variations in ceiling height while maintaining a tight, leak‑free connection. The adjustable configuration ensures optimal performance for any exhaust cabinet installation. The integrated brush‑sealed cable opening allows power cords to pass through without compromising the exhaust path. This exhaust brush feature preserves the integrity of the airflow while providing easy cable management. The sealed opening also helps protect equipment from dust and contaminants. The vertical duct pairs seamlessly with ZetaFrame® cabinets that feature solid rear doors, bottom panels, air dams, and snap‑in filler panels. When used with CPI's air director and containment accessories, it completes an effective airflow containment system. The modular design supports both new builds and retrofit projects across enterprise, hyperscale and edge data centers. By delivering a consistent and controlled cabinet exhaust flow, the vertical duct contributes to lower cooling costs and higher equipment reliability. CPI's global engineering expertise ensures the duct meets rigorous industry standards and is backed by comprehensive technical support. Choose the ZetaFrame® vertical duct to future‑proof your data center's thermal management strategy.</p>"},{"primaryId":"39873-E09","Primary ID":"39873-E09","Color":"Glacier White","Marketing Product Category ":"Cabinets & Enclosures","Marketing Product Family/Group":"Accessories","Marketing Product Subgroup":"Thermal Management","Marketing Product Series":"Vertical Exhaust Duct For ZetaFrame Cabinet","Marketing Description - Global English":"Vertical Exhaust Duct For ZetaFrame®Cabinet; For 27.6\"W (700 mm) x 41.3\"D (1050 mm) - 47.2\"D (1200 mm) Cabinet; 34”H-60”H (863 mm – 1523 mm); One Cable Opening; Glacier White","Shipping Weight":47,"Shipping Weight Uom":"LB","Ship Height":6,"Ship Height Uom":"in","Ship Length/Depth":114,"Ship Length/Depth Uom":"in","Ship Width":37,"Ship Width Uom":"in","Shipping Weight (Metric)":21.32,"Shipping Weight Uom (Metric)":"kg","Shipping Height (Metric)":15,"Shipping Height Uom (Metric)":"cm","Shipping Width (Metric)":94,"Shipping Width Uom (Metric)":"cm","Msrp $ Usd":1294.27,"Country Of Origin":"US","Certifications":["Not Applicable"],"Series Level Manual Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/a8d9feb5/66eca50606cc930019d6bbd2/ZETAFRAME_USER_MANUAL"],"Series Level Installation Instructions Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/c35d59b5/66eca58f06cc930019d6c0f8/39873_IIS"],"Promote on Website":"1","Attached to Series":"1","Height":"60\" (1524 mm)","Width":"23.8\" (605 mm)","Depth":"23.6\" (599 mm)","Cabinet Width":"27.6\"W (700 mm)","Duct Height":"34”-60”H (863 mm – 1523 mm)","BABA Compliant":"1","Product Height":60,"Product Height Uom":"\"","Product Length/Depth":23.6,"Product Length/Depth Uom":"\"","Product Width ":23.8,"Product Width Uom":"\"","Product Height (Metric)":1524,"Product Height Uom (Metric)":"mm","Product Depth (Metric)":599,"Product Depth Uom (Metric)":"mm","Product Width (Metric)":605,"Product Width Uom (Metric)":"mm","Product Weight":39,"Product Weight UOM":"LB","Short Description":"VED,700W,34-60H","Search Terms":"39873-E09,Vertical Exhaust Duct For ZetaFrame Cabinet,ZetaFrame Vertical Exhaust Duct For ZetaFrame Cabinet,Server cabinet Vertical Exhaust Duct For ZetaFrame Cabinet,Rack-mounted Vertical Exhaust Duct For ZetaFrame Cabinet,Data center Vertical Exhaust Duct For ZetaFrame Cabinet,Cabinet Vertical Exhaust Duct For ZetaFrame Cabinet solution,Network rack Vertical Exhaust Duct For ZetaFrame Cabinet,Structured cabling solution for Vertical Exhaust Duct For ZetaFrame Cabinet,Best Vertical Exhaust Duct For ZetaFrame Cabinet for server racks,How to organize cables with Vertical Exhaust Duct For ZetaFrame Cabinet,Efficient routing for Vertical Exhaust Duct For ZetaFrame Cabinet,Front-to-back cable routing for Vertical Exhaust Duct For ZetaFrame Cabinet,High-density cable organization for Vertical Exhaust Duct For ZetaFrame Cabinet,Professional cable management for Vertical Exhaust Duct For ZetaFrame Cabinet","Search Relevancy":2},{"primaryId":"39873-E10","Primary ID":"39873-E10","Color":"Glacier White","Marketing Product Category ":"Cabinets & Enclosures","Marketing Product Family/Group":"Accessories","Marketing Product Subgroup":"Thermal Management","Marketing Product Series":"Vertical Exhaust Duct For ZetaFrame Cabinet","Marketing Description - Global English":"Vertical Exhaust Duct For ZetaFrame®Cabinet; For 29.5\"W (750 mm) x 41.3\"D (1050 mm) - 47.2\"D (1200 mm) Cabinet; 34”H-60”H (863 mm – 1523 mm); One Cable Opening; Glacier White","Shipping Weight":49,"Shipping Weight Uom":"LB","Ship Height":6,"Ship Height Uom":"in","Ship Length/Depth":114,"Ship Length/Depth Uom":"in","Ship Width":37,"Ship Width Uom":"in","Shipping Weight (Metric)":22.23,"Shipping Weight Uom (Metric)":"kg","Shipping Height (Metric)":15,"Shipping Height Uom (Metric)":"cm","Shipping Width (Metric)":94,"Shipping Width Uom (Metric)":"cm","Msrp $ Usd":1364.11,"Country Of Origin":"US","Certifications":["Not Applicable"],"Series Level Manual Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/a8d9feb5/66eca50606cc930019d6bbd2/ZETAFRAME_USER_MANUAL"],"Series Level Installation Instructions Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/c35d59b5/66eca58f06cc930019d6c0f8/39873_IIS"],"Promote on Website":"1","Attached to Series":"1","Height":"60\" (1524 mm)","Width":"25.8\" (655 mm)","Depth":"23.6\" (599 mm)","Cabinet Width":"29.5\"W (750 mm)","Duct Height":"34”-60”H (863 mm – 1523 mm)","BABA Compliant":"1","Product Height":60,"Product Height Uom":"\"","Product Length/Depth":23.6,"Product Length/Depth Uom":"\"","Product Width ":25.8,"Product Width Uom":"\"","Product Height (Metric)":1524,"Product Height Uom (Metric)":"mm","Product Depth (Metric)":599,"Product Depth Uom (Metric)":"mm","Product Width (Metric)":655,"Product Width Uom (Metric)":"mm","Product Weight":40.7,"Product Weight UOM":"LB","Short Description":"VED,750W,34-60H","Search Terms":"39873-E10,Vertical Exhaust Duct For ZetaFrame Cabinet,ZetaFrame Vertical Exhaust Duct For ZetaFrame Cabinet,Server cabinet Vertical Exhaust Duct For ZetaFrame Cabinet,Rack-mounted Vertical Exhaust Duct For ZetaFrame Cabinet,Data center Vertical Exhaust Duct For ZetaFrame Cabinet,Cabinet Vertical Exhaust Duct For ZetaFrame Cabinet solution,Network rack Vertical Exhaust Duct For ZetaFrame Cabinet,Structured cabling solution for Vertical Exhaust Duct For ZetaFrame Cabinet,Best Vertical Exhaust Duct For ZetaFrame Cabinet for server racks,How to organize cables with Vertical Exhaust Duct For ZetaFrame Cabinet,Efficient routing for Vertical Exhaust Duct For ZetaFrame Cabinet,Front-to-back cable routing for Vertical Exhaust Duct For ZetaFrame Cabinet,High-density cable organization for Vertical Exhaust Duct For ZetaFrame Cabinet,Professional cable management for Vertical Exhaust Duct For ZetaFrame Cabinet","Search Relevancy":2},{"primaryId":"39873-E11","Primary ID":"39873-E11","Color":"Glacier White","Marketing Product Category ":"Cabinets & Enclosures","Marketing Product Family/Group":"Accessories","Marketing Product Subgroup":"Thermal Management","Marketing Product Series":"Vertical Exhaust Duct For ZetaFrame Cabinet","Marketing Description - Global English":"Vertical Exhaust Duct For ZetaFrame®Cabinet; For 31.5\"W (800 mm) x 41.3\"D (1050 mm) - 47.2\"D (1200 mm) Cabinet; 34”H-60”H (863 mm – 1523 mm); One Cable Opening; Glacier White","Shipping Weight":51,"Shipping Weight Uom":"LB","Ship Height":6,"Ship Height Uom":"in","Ship Length/Depth":114,"Ship Length/Depth Uom":"in","Ship Width":37,"Ship Width Uom":"in","Shipping Weight (Metric)":23.13,"Shipping Weight Uom (Metric)":"kg","Shipping Height (Metric)":15,"Shipping Height Uom (Metric)":"cm","Shipping Width (Metric)":94,"Shipping Width Uom (Metric)":"cm","Msrp $ Usd":1364.11,"Country Of Origin":"US","Certifications":["Not Applicable"],"Series Level Manual Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/a8d9feb5/66eca50606cc930019d6bbd2/ZETAFRAME_USER_MANUAL"],"Series Level Installation Instructions Link":["https://cdn.pimber.ly/public/asset/raw/663b2857ae13c25e14022b2b/c35d59b5/66eca58f06cc930019d6c0f8/39873_IIS"],"Promote on Website":"1","Attached to Series":"1","Height":"60\" (1524 mm)","Width":"27.9\" (709 mm)","Depth":"23.6\" (599 mm)","Cabinet Width":"31.5\"W (800 mm)","Duct Height":"34”-60”H (863 mm – 1523 mm)","BABA Compliant":"1","Product Height":60,"Product Height Uom":"\"","Product Length/Depth":23.6,"Product Length/Depth Uom":"\"","Product Width ":27.9,"Product Width Uom":"\"","Product Height (Metric)":1524,"Product Height Uom (Metric)":"mm","Product Depth (Metric)":599,"Product Depth Uom (Metric)":"mm","Product Width (Metric)":709,"Product Width Uom (Metric)":"mm","Product Weight":42.5,"Product Weight UOM":"LB","Short Description":"VED,800W,34-60H","Search Terms":"39873-E11,Vertical Exhaust Duct For ZetaFrame Cabinet,ZetaFrame Vertical Exhaust Duct For ZetaFrame Cabinet,Server cabinet Vertical Exhaust Duct For ZetaFrame Cabinet,Rack-mounted Vertical Exhaust Duct For ZetaFrame Cabinet,Data center Vertical Exhaust Duct For ZetaFrame Cabinet,Cabinet Vertical Exhaust Duct For ZetaFrame Cabinet solution,Network rack Vertical Exhaust Duct For ZetaFrame Cabinet,Structured cabling solution for Vertical Exhaust Duct For ZetaFrame Cabinet,Best Vertical Exhaust Duct For ZetaFrame Cabinet for server racks,How to organize cables with Vertical Exhaust Duct For ZetaFrame Cabinet,Efficient routing for Vertical Exhaust Duct For ZetaFrame Cabinet,Front-to-back cable routing for Vertical Exhaust Duct For ZetaFrame Cabinet,High-density cable organization for Vertical Exhaust Duct For ZetaFrame Cabinet,Professional cable management for Vertical Exhaust Duct For ZetaFrame Cabinet","Search Relevancy":2,"SKU Level SEO Page Title":"39873 Vertical Exhaust Duct for ZetaFrame® - Duct Seal | Chatsworth","SKU Level SEO Meta Description":"Discover the 39873 vertical exhaust duct for ZetaFrame® cabinets, featuring a duct‑sealing center point for reliable hot‑air return and easy cable entry.","SKU Level Web H4 Heading":"Key Features of the 39873‑E11 Exhaust Duct","SKU Level Web Paragraph Text":"<p>The 39873‑E11 provides a sealed pathway for hot‑air exhaust, directing airflow from the top of a ZetaFrame® cabinet to an overhead drop ceiling. Its design supports reliable operation of high‑density equipment housed within modern exhaust cabinets. By maintaining a controlled exhaust stream, the duct helps reduce cooling costs and improves overall data‑center efficiency. The duct sealing center point creates a continuous seal that accommodates variations in ceiling height while preventing air leakage. This feature simplifies installation and ensures consistent performance across diverse deployment scenarios. The two‑piece construction allows height adjustment from 34″ to 60″, making the product adaptable to a wide range of cabinet heights. Aluminum panels and plastic corners provide durability while keeping the weight manageable for field installation. The flexible top seal conforms to ceiling tolerances, eliminating the need for custom fabrications. A brush‑sealed cable opening on the rear enables power cords to pass through without compromising the seal. This integration reduces the number of penetrations required and maintains the integrity of the containment system. The vertical exhaust duct is supplied with all necessary hardware for quick attachment to solid rear doors, bottom panels, and air directors. CPI offers engineering support to ensure the duct aligns with specific airflow strategies. Selecting the 39873‑E11 enhances the thermal management of any ZetaFrame® enclosure while delivering the reliability expected from Chatsworth Products.</p>"}],"options":{"Cabinet Width":["23.6\"W (600 mm)","27.6\"W (700 mm)","29.5\"W (750 mm)","31.5\"W (800 mm)"],"Duct Height":["15”-20”H (381 mm – 508 mm)","20”-34”H (508 mm – 863 mm)","34”-60”H (863 mm – 1523 mm)"],"Color":["Black","Glacier White"]},"total":24}